DivLine S-O
40.1
This function divides the line between the instrument and the first target by an input
span number. It then guides you to stake out the points, one by one.
1.
Press
[3]
or select
DivLine S-O
in the
Stakeout menu.
2.
Set up the baseline. To do this, sight the target
on the line (the end point) and press
[MSR1]
or
[MSR2]
.
3.
Enter the total stake number in the Span total
field.
The observation screen for the first stake (from
the instrument) appears.
4.
Sight the prism and press
[MSR1]
or
[MSR2]
.
5.
Use
[^]
or
[v]
to change the guide point. You can
calculate and guide up to double the number of
the stakes.
6.
To record the point as an SO record, press
[ENT]
.