4
Applications
64
Total Station DTM-302 Series Instruction Manual
1.
To start the resection, press
[2]
or select
Resection
in the Stn Setup menu.
2.
Enter the point name for the first observation
point (PT1).
3.
Enter the target height and press
[ENT]
.
4.
Sight PT1 and press
[MSR1]
or
[MSR2]
.
To use the
F2
softkey for F1/F2
measurements, see Advanced feature:
Measuring F1 and F2, page 61.
5.
To proceed to the next point, press
[ENT]
.
6.
Enter the second point (PT2) and its height of
target.
The
F2
softkey is not available on the DTM-332.