Applications
4
Total Station DTM-302 Series Instruction Manual
101
6.
To record the point, enter a PT (and CD) value
and press
[ENT]
. The height of target is fixed to
0.0000 for the offset point.
Sample records
SS, 40, 0.0000, 48.3304, 169.20370, 82.02470, 10:52:37
CO, PT1, 0.0000, 48.3020,169.19165, 83.58565
CO, PT2, 0.0000, 48.3155,168.54250, 85.42440
CO, O/S MSR:40 0.0000 0.0000 169.20370 87.02340
The calculated point (TGT) is stored as a SS record.
Measurements to the first and second target (P1 and P2) are stored as comment
records (PT1 and PT2). The last record records the angle measurement to the ALT
(vertically offset point from the actual target point).