![Nikon DTM-302 Series Скачать руководство пользователя страница 184](http://html1.mh-extra.com/html/nikon/dtm-302-series/dtm-302-series_instruction-manual_1690219184.webp)
6
Checking and Adjustment
166
Total Station DTM-302 Series Instruction Manual
12.
Calculate the average of all the values of RP, and the average of all the values of
RQ.
13.
Compare the value of PQ to averaged RP + averaged RQ. The difference should
be within the specified range of error for the instrument (±3 mm + 2 ppm ×
distance).
At 100 m distance, the error range is ±3.2 mm. If the error is out of range,
contact your dealer.