NE200&300 Quick Start Guide
48
Code
Description
Setting range
Default
Modify
Modbus
Address
F7.21
②
Y1 function
definition
4: Output voltage
(0
~
Max Voltage)
5: PID setup (0
~
10V)
6: PID feedback
(0
~
10V)
7: Calibrating signal
(5V)
8: Output torque
(0
~
2 times of motor
rated torque)
9: Output power
(0
~
2 times of drive
rated power)
10: Bus voltage
(0~1000V)
11: 9: AI1 (0
~
10V)
12: AI2 (0
~
10V/4
~
20mA)
13: Pulse frequency
14: Communication
setting
15: Reserve
16: Current output
(0~2 time rated
value)
0
○
0815H
③
DO output
selection
0
○
0815H
F7.22
②
AO output
range selection
0: 0
~
10V/0
~
20mA
1: 2
~
10V/4
~
20mA
0
○
0816H
③
AO1 output
range selection
0816H
F7.23
②
Reserve
Reserve
Reserve
Reserve
0817H
③
AO2 output
range selection
0: 0
~
10V/0
~
20mA
1: 2
~
10V/4
~
20mA
0
○
0817H
F7.24
②
Gain of AO
1
~
200%
100%
○
0818H
③
Gain of AO1
0818H
F7.25
②
Reserve
Reserve
Reserve
Reserve
0819H
Gain of AO2
③
1~200%
100%
○
0819H