NE200&300 Quick Start Guide
42
Code
Description
Setting range
Default
Modify
Modbus
Address
41: Actual length clear
42: FWD running
(FWD NC)
43: REV running (REV
NC)
44: HLD (Normally
open)
45: Increase torque
46: Torque increment
clear
47: Decrease torque
48: One key recover
user parameters(Valid
in stop state)
49~56: Reserved
57: Pulse input (Take
X4 in case 2 inputs)
F6.10
Analog
Nonlinear
Selection
0: none
1: AI1
0
×
070AH
2: AI2 3: Pulse
F6.11 AI1 Min. input
0.00
~
F6.13
0.00V
○
070BH
F6.12
AI1 Min. input
corresponding
setup
-200.0
~
200.0%
0.00%
○
070CH
F6.13 AI1 Max. input F6.11
~
10.00V
10.00V
○
070DH
F6.14
AI1 Max. input
corresponding
setup
-200.0
~
200.0%
100.00%
○
070EH
F6.15
AI1 input filter
time
0.01
~
50.00s
0.05s
○
070FH
F6.16 AI2 Min. input
0.00
~
F6.18
0.00V
○
0710H
F6.17
AI2 Min. input
corresponding
setup
-200.0
~
200.0%
0.00%
○
0711H
F6.18 AI2 Max. input F6.16
~
10.00V
10.00V
○
0712H