04.
Release the keys when the manoeuvre starts (after approx. 3 seconds);
05.
Wait a few seconds for the control unit to complete the position learning
phase: pole closing, opening and closing .
06.
Press “
Open
” for the pole to run a complete Opening manoeuvre .
07.
Press “
Close
” for the pole to run a complete Closing manoeuvre .
During these manoeuvres, the control unit memorises the force required to
complete these manoeuvres .
CAUTION! – The learning phases must never be interrupted.
If this
occurs, the entire learning procedure must be repeated .
At the end of the learning phase, if leds “L3” and “L4” flash, this means that
there is an error . The phase for learning the mechanical stops can be repeated
at any time, also after installation (for example, if the position of a mechanical
stop is moved) .
IMPORTANT
– The deceleration points are calculated automatically by the
control unit; after the position search phase, at least 2 or 3 complete manoeu-
vres must be performed before that control unit can correctly calculate the
points of deceleration .
4.6 - Pole movement check
After learning the devices and completing the 2-3 manoeuvres to calculate
deceleration, a number of Opening and Closing manoeuvres should be per-
formed to ensure correct pole movement .
01.
Press “
Open
” to activate an Opening manoeuvre; ensure that the pole
starts to decelerate before reaching the opening position;
02.
Press “
Close
” to activate a Closing manoeuvre; ensure that the pole starts
to decelerate before reaching the closing position;
03.
Make sure that the (optional) LED flashing light flashes at regular intervals
(0 .5 sec on, 0 .5 sec off) during a manoeuvre .
04.
Run a number of Opening and Closing manoeuvres to ensure that there
are no points of increased friction or malfunctions .
CAUTION
– If the manoeuvre starts from a position different from that of one of
the mechanical stops (opening or closing), it is performed at low speed .
4.7 - Connecting a radio receiver
The control unit is fitted with a SM type connector for connection of a radio
receiver (optional accessory) model SMXI, SMXIS, OXI or OXIT and similar.
To insert the radio receiver, disconnect the control unit from the power mains
and insert the receiver as shown in
fig. 28
.
Table 4
shows the actions performed by the control unit according to the out-
puts activated or the commands sent from the radio receiver .
4.8 - Connecting the pole lights (optional accessory)
01.
Move the pole to the vertical position;
02.
Unscrew the 4 screws that hold the pole cover (
fig. 29
);
03.
Remove the pole temporarily;
04.
Insert the grommet in the pre-drilled hole for cable routing (
fig. 30 - A, B
);
05.
Route the lights cable through the impact protection rubber profile, using a
guide to facilitate attachment if necessary (
fig. 31 - A, B
);
06.
If necessary, shorten the length of the lights cable: cuts may only be made
at the points bearing the relative mark . After cutting, the plug at the cut end
must be moved to seal off the new end;
07.
Insert the cable first through the hole on the pole support and then through
the hole on the cabinet (
fig. 32 - A, B, C
);
Caution
– Leave a little extra
cable in the pole support, to enable pole rotation through 90° without ten-
sioning the cable;
08.
Connect the lights cable to the FLASH terminal on the control unit: see
diagram in
fig. 27
;
09.
Position and secure the connector in the slot on the pole (
fig. 32 - D
);
10.
Insert the pole and secure with its cover, tightening the 4 screws fully down
and taking care not to pinch the wiring cable (
fig. 33
) .
4.9 - Connecting the LED flashing light mod. XBA7 or LED traf-
fic light mod. XBA8 (optional accessories)
On the cover of the barrier a LED flashing light mod. XBA8 may be fitted. The
operating mode of this flashing light may be modified through the Oview pro-
grammer or with suitable programmes of the control unit . For further informa-
tion, refer to the instruction manual for the product .
4.10 - Connection of other devices
S4BAR also enables power supply to external devices (a radio receiver or key-
operated selector switch lighting) by receiving power from the control unit: for
the type of connection, see
Fig.
34
.
The power supply voltage is 24 Vdc, -30%/+50%, with maximum available cur-
rent 100 mA .
4.10.1 - Programming unit Oview
The use of the programming unit Oview enables complete and rapid manage-
ment of installation, maintenance and troubleshooting of any malfunctions of
the whole automation system . Oview can be connected to S4BAR by means of
the BusT4 connector on the control unit .
To access the BusT4 connector, open the cover of S4BAR and insert the con-
nector in its seat (
fig.
35
) .
In general, Oview can be positioned at a maximum distance of 100 m of cable
from the control unit; it can be connected to multiple control units simultane-
ously (max. 16) and can also remain connected during normal operation of the
automation; to exceed these limits, observe the warnings in the Oview instruc-
tion manual and the Oview System Book system manual. If a OXI type radio
receiver is present in the control unit, Oview enables access to the parameters
of the transmitters memorised in this receiver . For detailed information, refer
to the instruction manual of the Oview programmer or the “S4BAR” function
datasheet also available on the website
www.niceforyou.com
4.10.2 - Buffer battery mod. PS124 (accessory)
In the event of a mains power failure, S4BAR can also be powered by a buffer
battery model PS124 . To install and connect the battery, proceed as follows:
Caution! – The electric connection of the battery to the control unit
must only be made after completing all installation and programming
phases, as the battery constitutes an emergency power supply.
01.
Connect the relative cable of the buffer battery and position the battery as
shown in
fig. 36
;
03.
Remove the membrane on the control unit (
fig. 37
);
04.
Disconnect the mains power and fit the connector as shown in
fig. 38
.
4.10.3 - Solemyo System (photovoltaic supply)
S4BAR is designed to be powered with the “Solemyo SYKCE” photovoltaic
system . To connect IT to the control unit, use the socket that is normally used
for the buffer battery (see paragraph 4 .10 .2) .
IMPORTANT!
- When S4BAR is powered by the “Solemyo” system, it MUST NOT BE
POWERED at the same time from the electrical mains.
- Due to the limited solar power available, depending on the installation
location and time of year, S4BAR can perform a maximum number of
manoeuvres per day. Before installing the Solemyo system, check in
the relative instruction manual whether the maximum number of pos-
sible manoeuvres is compatible with the intended use.
- The Solemyo system can only be used efficiently if the control unit is
active and set with the Standby function set to “All” mode (only pos-
sible using the Oview programmer).
TABLE 4
SMXI, SMXIS Receiver
output description
Output no . 1
Step by step
Output no. 2
Partial Open (opens to approx. 45%;
value programmable with Oview, see paragraph 4 .10 .1)
Output no . 3
Open
Output no . 4
Close
OXI receiver, OXIT programmed in “Extended Mode II”
Command description
Command no . 1
Step by step
Command no. 2
Partial Open (opens to approx. 45%;
value programmable with Oview, see paragraph 4 .10 .1)
Command no . 3
Open
Command no . 4
Close
Command no . 5
Stop
Command no . 6
Apartment block Step by Step
Command no . 7
Step-Step High priority
(controls also if automation is blocked)
Command no. 8
U Open
Command no. 9
U Close
Command no . 10 Open and block automation
Command no . 11 Close and block automation
Command no . 12 Block automation
Command no . 13 Release automation
Command no . 14 Courtesy light timer on
Command no . 15 Courtesy light on-off
Содержание S4BAR
Страница 2: ......
Страница 20: ......
Страница 40: ......
Страница 60: ......
Страница 80: ......
Страница 100: ......
Страница 120: ......
Страница 140: ......
Страница 143: ...I I 1 A B C B 330 mm 2 179 5 mm 1146 mm 826 mm 4000 mm 3 b a d e f g h c...
Страница 144: ...II II 5 A B C 1 2 4...
Страница 145: ...III III 9 10 90 6 A C B 7 8 B A...
Страница 146: ...IV IV 14 A B 15 A B 11 A B 12 13 A B...
Страница 147: ...V V 16 A B 17 18...
Страница 148: ...VI VI 20 180 21 C C A B 1cm 1cm 19 A C B...
Страница 149: ...VII VII 22 23 26 L N 24 1 2 25...
Страница 151: ...IX 30 A A B STOP 31 A B...
Страница 152: ...X 32 A B C D STOP 33 A B 34...
Страница 153: ...XI 35 36 L7 L8 37 A B L7 L8 2 1 L8 L7 L8 L8 L7 L8 A B C Op L5 L6 L7 L8 Stop Set Close F u s e 1 A T 38...
Страница 154: ...XII 300 200 700 500 39 300 200 700 500 150 40 41...
Страница 155: ...a c d e b F2 F1 42 43 XIII...
Страница 156: ...XIV 44 O pe n L1 L2 L3 L4 L5 L6 L7 L8 St op Se t Cl os e Fuse 1AT 45 f g...
Страница 157: ......
Страница 158: ......
Страница 159: ......
Страница 160: ...IST S4BARR02 4865_14 02 2017 www niceforyou com Nice S p A Via Pezza Alta 13 31046 Oderzo TV Italy info niceforyou com...