![Nice HySecurity SlideSmart DC Series Скачать руководство пользователя страница 63](http://html1.mh-extra.com/html/nice-hysecurity/slidesmart-dc-series/slidesmart-dc-series_installation-and-programming-manual_1687273063.webp)
DISPLAY AND MENU OPTIONS
Table 10. Smart DC Controller - Installer Menu Functions
Ref.
No.
User Menu
Display
Setting Options
(Bold = Factory
Settings)
Menu Tasks and Explanations
DC Controller
Display
Connections
9
SG 0 (OFF)
SEQUENCED GATE
0 = solo
operator
1 = Loop View #1
2 = Loop View #2
3 = Loop View #3
4 = Loop View #4
Establishes communication after
wiring two or more gate operators
as sequential gates. This SG menu
item only appears if the Dual Gate
menu item (DG) is set to 0 (solo
operator).
NOTE:
After selecting
SG settings, consider accessing the
User Menu in each gate operator
to address the Close Timer (CT)
setting.
*See note on previous
page. Use shielded
cable to DUAL GATE
input terminals on
both operators. Pair
wires: A - A, COM -
COM, and B - B. Dual
Gate wiring requires
3 wires.
10
CH 0 (AC)
CHARGER TYPE
0 = AC powered
charger
1 = Solar
Assigns charger type usually set at
factory. If set to solar at factory then
this menu item is hidden.
(N/A)
11
BT 0 (STANDARD)
BATTERY TYPE
0 = standard
(8Ah)
1 = extended
(50Ah)
2 = maximum
(110Ah)
Assign the battery type used by the
operator.
NOTE:
Smaller batteries
are charged with less current
to avoid overheating and larger
batteries are charged with more
current to supply a more rapid
charge.
Extended (50Ah)
batteries require
wire extensions and
shelf installation.
Maximum (110Ah)
batteries require
separate housing
and wiring.
12
FO 0 (OFF)
FIRE DEPT OPEN
0 = disabled
1 = enabled
Enables Fire Department Open
input. When set to 1, signal received
through this input overrides all
photoelectric eyes and edge
sensors and opens gate. Pressing
RESET button (or the OPEN push
button) is required before gate can
be closed.
+24V DC
EMERG OPEN
13
SE 2
IES SENSITIVITY
0 = maximum
sensitivity
2 = default
sensitivity
9 = least
sensitivity
Adjusts the sensitivity of the internal
inherent entrapment sensor (IES).
Available settings are 0 to 9 with 9
being the least sensitive. HySecurity
strongly recommends that you
avoid setting the IES sensitivity
higher than 6.
NOTE:
Before
changing the IES sensitivity, make
sure that the gate rolls smoothly
without obstruction. Fix any issues
with gate hardware.
See Note.
MX4505 Rev. E ©2020
SlideSmart DC Programming and Operations
hysecurity.com | 800-321-9947
63