![Nice HySecurity SlideSmart DC Series Скачать руководство пользователя страница 56](http://html1.mh-extra.com/html/nice-hysecurity/slidesmart-dc-series/slidesmart-dc-series_installation-and-programming-manual_1687273056.webp)
ADJUSTING GATE SPEED
The gate speed can be increased or decreased
a ¼ foot per second from the operator’s default
speed. See Figure 49
To adjust the gate speed, take the following steps:
1.
At a gate status display, press the MENU button
twice. The CLOSE TIMER display appears.
2.
Simultaneously, press the OPEN and RESET
buttons to enter the Installer Menu. Release
the buttons and the LEARN LIMITS display
appears. It is the
fi
rst item in the Installer Menu.
3.
Press NEXT until the OPEN SPEED (or CLOSE
SPEED) display appears. Select the desired
setting based on the operator type:
SlideSmart DC 15
0 = 0.75 ft/s
1 = 1.0 ft/s
(Usage Class 3 & 4 only)
2 = 1.25 ft/s
SlideSmart DC 10F
4 = 1.75 ft/s
(The DC 10F is designed for
Usage Class 3 & 4 sites only)
5 = 2.0 ft/s
6 = 2.25 ft/s
4.
Use the SELECT and NEXT buttons to navigate
and change the speed setting on the display.
5.
To exit the Installer Menu, press the MENU
button. The gate status appears in the display
indicating you have returned to Run Mode.
NOTICE
Two options, one for OPEN SPEED the other
for CLOSE SPEED, appear in the Installer
Menu. The steps involved in changing the
open speed are shown below. The steps to set
the close speed are the same, you just need
to access the CLOSE SPEED option.
NOTICE
Certain speeds are allowed only when the
operator’s Usage Class is set appropriately.
Figure 49. Adjusting Gate Speed
CT 0 (OFF)
CLOSE TIMER
OPEN
CLOSE
STOP
MENU
RESET
PREV
NEXT
SELECT
HYSECURITY
GATE CLOSED
OPEN
CLOSE
STOP
MENU
RESET
PREV
NEXT
SELECT
1. Start at a gate
status display.
2. To access the
User Menu,
press the MEN
button twice.
3. Access the
Installer Menu,
simultaneously,
pressing the
OPEN and
RESET
buttons.
4. Use NEXT to
navigate to the
menu display.
Change the
setting using th
SELECT and
NEXT buttons.
OS 5
OPEN SPEED
OPEN
CLOSE
STOP
MENU
RESET
PREV
NEXT
SELECT
LL 0 (OFF)
LEARN LIMIT
OPEN
CLOSE
STOP
MENU
RESET
PREV
NEXT
SELECT
DISPLAY AND MENU OPTIONS
MX4505 Rev. E ©2020
56
hysecurity.com | 800-321-9947
SlideSmart DC Programming and Operations