USING AN EXISTING PAD
In many applications, SlideSmart may be a
replacement operator for an existing gate system.
Make sure the pad is level and inspect the pad for:
Compliance with local building codes.
Appropriate distance from the gate. See Figure
3.
Appropriate dimensions (See Figure 3) for
SlideSmart installation.
Durability.
INSTALLATION
To use an existing pad, take the following steps:
1.
Remove any existing equipment from the pad.
2.
Measure the pad to ensure it is sized properly
for SlideSmart.
3.
Check the mounting hole locations and re-drill,
if necessary.
4.
Follow the steps in
"Concrete Pad Mount" on
page 22
.
CAUTION
Consider positioning the operator so existing
conduit enters the cutout in the SlideSmart
base plate. Cutting small holes in the plastic
base plate and cover for pre-existing conduit
is permissible. Two 0.875-inch (22mm) diameter
holes for running conduit are also provided on
both sides of the chassis. See Figure 4.
Figure 3. Conduit Side View
Side View
7
¾"
(19.7cm)
Gate
Chain to Gate
Ideal distance = 3-1/4" (8.25cm)
Min. distance = 2-1/2" (6.4cm)
Chain
height
Grade
level
Concrete pad
Cut out
if rear
install
Conduit cut outs
Figure 4. Conduit Cut Out Views
MX4505 Rev. E ©2020
18
hysecurity.com | 800-321-9947