ENABLING THE FIRE DEPARTMENT
OVERRIDE
Many counties and cities require a Fire Department
override system for gate operators. The fire
department’s alert system is a separate unit that
must be connected to the Smart DC Controller.
The FIRE DEPARTMENT OPEN option must be
properly con
fi
gured through the Installer Menu
before the operator will recognize the alert system.
To enable the Fire Department Override, take the
following steps and see Figure 54 and Figure 55:
1.
Connect the NO contact from the alert system
or key switch to the following Smart DC
Controller terminals: EMERG OPEN and +24V.
2.
Con
fi
gure the Installer Menu. At a gate status
display, press the MENU button twice. This
accesses the User Menu and the CLOSE TIMER
display appears.
3.
Simultaneously, press the OPEN and RESET
buttons to enter the Installer Menu. Release
the buttons and the USAGE CLASS display
appears. It is the
fi
rst item in the Installer Menu.
4.
Press NEXT until the FIRE DEPARTMENT
OPEN display appears. The factory default
setting is 0.
5.
Use the NEXT button to change the number
on the display to 1 and then press SELECT.
6.
To exit the Installer Menu, press the MENU
button. The gate status appears in the display
indicating you have returned to Run Mode.
Figure 54. Fire Department Override Connections
COM
STOP
OPEN
RADIO
CLOSE
OPEN
OPEN
PARTIAL
EYE
OPEN
EYE
CLOSE
EXIT
LOOP
BLOCK
EXIT
IN OBS
LOOP
OUT OBS
LOOP
CENTER
LOOP
EDGE
EYE
COM
+ 24 V
EMERG
OPEN
SHOW
LEDs
FIRE
Figure 55. Fire Department Override Menus
CT 0 (OFF)
CLOSE TIMER
OPEN
CLOSE
STOP
MENU
RESET
PREV
NEXT
SELECT
HYSECURITY
GATE CLOSED
OPEN
CLOSE
STOP
MENU
RESET
PREV
NEXT
SELECT
1. Start at a gate
status display.
2. To access the
User Menu,
press the MENU
button twice.
3. Access the
Installer Menu, by
simultaneously,
pressing the
OPEN and
RESET
buttons.
4. Use NEXT to
navigate to the
menu display.
Change the
setting using the
SELECT and
NEXT buttons.
FO 1
FIRE DEPT OPEN
OPEN
CLOSE
STOP
MENU
RESET
PREV
NEXT
SELECT
LL 0 (OFF)
LEARN LIMIT
OPEN
CLOSE
STOP
MENU
RESET
PREV
NEXT
SELECT
MX4505 Rev. E ©2020
60
hysecurity.com | 800-321-9947
SlideSmart DC Programming and Operations