TROUBLESHOOTING THE POWER
TRANSISTOR
Checking the power transistor
Disconnect the connections to the compressor on the
inverter board PWB2 and measure between the connec-
tions in accordance with the table:
Normal values (Ω)
Measurement points
AMS 10-12/-
16
AMS 10-8
Connection (-
)
Connection
(+)
~ 1 MΩ
0 and the
value in-
creases
N
P
~ 300-400 kΩ
P
N
0
Several MΩ
and the value
rises
U
P
V
P
W
P
~ 1.2 MΩ
~ 650 kΩ
U
N
V
N
W
N
~ 1.3 MΩ
~ 670 kΩ
P
U
~ 4.4 MΩ
P
V
P
W
0
~ 650 kΩ
N
U
~ 4.8 MΩ
N
V
~ 4.9 MΩ
N
W
Location of measurement points
The power transistor’s connection P
P
The power transistor’s connection N
N
Red connection to compressor
U
White connection to compressor
V
Black or blue connection to compressor
W
AMS10-12
U
V
W
P
N
AMS10-8
P
N
U
V
W
53
Chapter 6 | Troubleshooting
NIBE AMS10
Содержание SPLIT AMS 10