Filter board PCB (PWB3)
Filter PCB
NOTE
Wait at least three
minutes after cut-
ting the current!
1
. First remove the PBC con-
trol board.
T6
Strap
CNW
T10
T11
CNO2
T5
CNO1
T4
T9
CNA2
T2
T1
T8
CNW2
Lock
support
Strap
Lock
support
Lock
support
Lock
support
2
. Cut off the straps.
3
. Disconnect the contacts
CNA2 and CNO2 on the filter
board.
4
. Disconnect and remove the
ground cable.
5
. Disconnect contacts in the
following order:
1.
On the inverter board:
T21 for T5
T22 for T6
2.
On the control board:
CNW for T10
CNW for T11
3.
On contact terminal
board:
L1 for T1
N for T2
1 for T8
2 for T9
6
. Clamp together the heads
of the lock supports.
7
. Remove the PBC filter
board.
69
Chapter 7 | Component replacement
NIBE AMS10