Fan and fan motor (FM01)
CNFAN
Clamp
4
. Disconnect the connection
to CNFAN.
5
. Detach the clamp.
Control unit
Tape
Fan cabling
6
. Remove tape and fan
cabling.
4 screws
2 metal clamps
7
. Detach the two metal
clamps.
8
. Undo the four screws and
remove the fan motor.