GENERAL DESCRIPTION
NB: The routing from DSP channels (from 1 to 4 on the front panel) and the output speakon (from A to D on the
back panel) is done automatically regarding setup configuration. See Input Patch menu further in the manual.
You can see with the gray line on the above drawing that unused pins on output
speakon are shorted together, but are not connected to ground. Therefore be careful as
very high voltage might be present on these unused pins.
User interface block
The user interface block has already been described through the front panel description in
the first part of this document. Please note that all the commands and displays are
available through the ESmonitor™ software by Auvitran, through the Ethersound™ network
(except the mains switch).
Communication block
The communication block regroups the RS232 port (on a sub-D9 plug) and the GPIO port
(on a sub-D25 plug).
The RS232 port is mainly used to upgrade the firmware of the unit from a PC computer, or
to connect a NEXO DPU (Digital Patching Unit). The pin-out is given bellow:
The RxD pin is the “Receive data” pin from the NXAMP point of view. Thus this is an input.
The TxD pin is the “Transmit data” pin from the NXAMP point of view. Thus this is an
output. GND is the ground.
A crossover cable (connecting RxD pin of NXAMP to TxD pin of computer, and so on) is
needed to use this serial port. Please see further the dedicated part of this document on
that subject.
The GPIO port is a Global Purpose Input/Output signals system that can be use for a wide
range of application, including interfacing the NXAMP with security systems and
communication with NEXO DMU (Digital Meters Unit). There are the following signals
available:
•
8 x General purpose output signals from NXAMP (5 Volts signals)
•
5 x General purpose input signals to NXAMP (5 Volts signals)
PAGE 33 OF 140
Содержание NXAMP4X1
Страница 2: ......
Страница 110: ...DMU DIGITAL METERS UNIT FOR NXAMP PAGE 110 OF 140 ...
Страница 118: ...DPU DIGITAL PATCHING UNIT FOR NXAMP SPK8 To STM Stack SPK4 Link between DPUs PAGE 118 OF 140 ...
Страница 125: ...NXWIN4 SOFTWARE FOR NXAMP FIRMWARE UPGRADE PAGE 125 OF 140 ...
Страница 139: ...ROHS CERTIFICATE ROHS certificate PAGE 139 OF 140 ...