NXAMP TECHNICAL SPECIFICATIONS
NXAMP TECHNICAL SPECIFICATIONS
POWER SPECIFICATIONS FOR NXAMP Powered TDcontroller
Number of channels
4 channels, 3 channels (2 non b 1 bridged) or 2 channels (2 bridged)
NXAMP4X1
NXAMP4X4
Max. output power (8
Ω
) 600 W (non bridged)
1900 W (non bridged)
1800 W (2 channels bridged)
6600 W (2 channels bridged)
Max. output power (4
Ω
) 900 W (non bridged)
3300 W (non bridged)
2600 W (2 channels bridged mode)
8000 W (2 channels bridged)
Max. output power (2
Ω
) 1300 W (non bridged)
4000 W (non bridged)
Power consumption
10 W Standby, 100 W Idle, 1100 W 1/8 Power 20 W Standby, 150 W Idle, 3000 W 1/8 Power
SPECIFICATIONS FROM ANALOG IN TO POWER OUT
Analog Inputs channels
4 channels analog inputs on XLR 3 with a second XLR 3 for linking
Frequency response
+/- 0.5 dB from 10 Hz to 20 KHz
Input Impedance
20 KOhm.
Max Input Level
+28 dBu
Dynamic Range
All Channels = 105dB unweighted
THD + Noise
Typical 0.1% flat setup
Latency time
2.2 ms on a flat setup (Compatible with NX241 and NX242)
Power Supply
Dedicated version for 100 ~ 120 Volts or 220 ~ 240 Volts
FRONT AND BACK PANEL FEATURES
Audio Inputs
•
4 balanced analog inputs on XLR with link, using 24 bit converters.
•
4 digital inputs via the optional network card slot at the back.
Power Outputs
4 Speakon outputs
RS232 port
Allow firmware upgrade for software improvement and new cabinet setups.
GPIO port
5 Global Purpose Inputs and 8 Global Purpose Outputs
Front Panel
On/Off switch, Wheel, A/B buttons, 40 char x 2 display. Amp protect/Stand-by/Power LED’s.
For each ch: volume (15 LEDs), Mute w LED, Output current LED, Protect LED, Peak LED.
Rear Panel
1 mains socket (2 for NXAMP4X4); RS232; GPIO, Expansion slot, 4 XLR w link, 4 Speakon 4
NXAMP4X1
NXAMP4X4
Dimensions & Weight
3U 19" Rack, 457 mm (18") Depth, 16.5kg
(36 lbs) net
4U 19" Rack, 457 mm (18") Depth, 24.5kg
(54 lbs) net
USER CONTROLS
System Selection
Allows control from all NEXO ranges.
System Set-up
Within the selected range when possible, allows the cabinet to be set for passive/active mode,
wideband/crossover mode, choose among crossover point, cardiod/supercardiod mode.
Protection
Multiple Peak Limiters fitted for both selected cabinet and amplifier. Multiple Acceleration,
Displacement and Temperature protections on every channel.
Delay
Up to 66m (145 ft.) of delay in 10cm (.4in ) steps
Input Patching
Any of the 4 analog (or 8) inputs combination to be routed on each output.
Output Gain
Channel gain +/-6dB in 0.5dB steps.
Volume control
Each channel with 16 steps from – inf dB to 0 dB.
Save/Recall
Set-up Stores 32 user set-ups
Array EQ
LF/HF shelving filters to compensate ground/stacking effects, +/-6dB
Security Mode
Password protected for Read-Only or Remote-Only Mode.
Remote control
Full remote control via the Ethersound protocol and ESmonitor™ software.
Certification
UL, SEMKO (CE), CCC, KOREA, TSS, PSE
Green status
Compliant with ROHS and WEEE directive
PAGE 126 OF 140
Содержание NXAMP4X1
Страница 2: ......
Страница 110: ...DMU DIGITAL METERS UNIT FOR NXAMP PAGE 110 OF 140 ...
Страница 118: ...DPU DIGITAL PATCHING UNIT FOR NXAMP SPK8 To STM Stack SPK4 Link between DPUs PAGE 118 OF 140 ...
Страница 125: ...NXWIN4 SOFTWARE FOR NXAMP FIRMWARE UPGRADE PAGE 125 OF 140 ...
Страница 139: ...ROHS CERTIFICATE ROHS certificate PAGE 139 OF 140 ...