© 2020 Copyright Newmar Corporation. All rights reserved. For the most up-to-date version of this content, and for more product-specific information, please refer to Newgle.
161
PLUMBING
If the pump is running, but there is no water:
•
Fill the tank.
•
Clear the water line to the pump or the pump inlet
filter.
•
Rotate the city water / tank fill valve to the correct
position.
If the pump isn’t running:
•
Check the pump switch.
•
Check the 12 Volt fuses.
•
Check the electrical connections.
•
Check the battery.
Your installed bathroom and kitchen faucets and fixtures are available in many styles, finishes, and
configurations, often complementing the other fixtures in your coach.
With proper maintenance, the faucets in the
coach should provide years of trouble-free usage. The faucets
and fixtures can be cleaned by wiping with a soft, damp cloth.
Washing with warm water will remove dry water spots. Turn o
ff
the water and drain the pressure before attempting repair or
replacement of the faucet.
Faucets and Fixtures
Water Filter Care and Maintenance
This article provides basic care and maintenance recommendations for water filters. Your coach may be equipped with a
fresh water filtration system. This system uses extruded carbon filter cartridges to remove sediment and certain impurities
from the incoming water supply. The filter assembly is located in the basement water compartment. Select coach models
may also have additional filters installed for drinking water.
Filters
Avoid using “S.O.S.” type cleaning pads or other
abrasive cleaners because they may scratch the
surface. Do not use cleaners that contain harsh or
abrasive chemicals. Alcohol or similar solvents should
never be used.
IMPORTANT
!
Water Pump Operation via SilverLeaf
This article provides a basic overview of the water pump operation via the
SilverLeaf system. The water pump may be operated from one or multiple
locations, depending on the coach model, year, and floorplan.
The SilverLeaf TM-102 module receives inputs from the water pump button
or switch on the SilverLeaf touchscreen panel, the remote monitor panel
in the water compartment, or the KIB V-BUS switch panel(s) (if equipped).
By activating the water pump button or switch, the TM-102 energizes the
water pump relay in the KIB circuit board, which grounds the circuit. Once
the pump pressure switch makes contact, the pump will supply water
pressure to the fresh water system. The pump will shut o
ff
once the pump
pressure switch is satisfied.
SilverLeaf Touchscreen:
•
May be located in the overhead control panel, bedroom, or in the middle
of the coach on the wall
SPX-300 Display:
•
May be located in the exterior water compartment
KIB LCD Touchscreen:
•
May be located in various locations throughout the coach
•
May be used in conjunction with the Silverleaf system