![Neuromeka INDY7 Скачать руководство пользователя страница 307](http://html1.mh-extra.com/html/neuromeka/indy7/indy7_user-manual_1676318307.webp)
307
08
|
Maintenance and Repair
8.5
How to Measure Insulation Resistance
A multimeter is required to measure insulation resistance. When checking, turn off the power and
disconnect the power cable completely from the power socket. Make a report after measurement
to check the variation in resistance value at each inspection.
Measuring Insulation Resistance in AC Input Stage
Measure the AC input terminal with the multimeter as follows.
The normal range is as follows.
Inspection item
Connection terminal
Normal value
AC power input
AC220.L
–
AC220.N
50 kΩ
or larger
AC220.L
–
F.G.
1 M
Ω
or larger
AC220.N
–
F.G.
1 M
Ω
or larger
Measuring Insulation Resistance in DC Output Stage
Measure the DC output terminal with a multimeter as follows.
The normal range is as follows.
Inspection item
Connection terminal
Normal value
DC power output
DC48V - GND
1
0 kΩ
or larger
DC24V - GND
70
0 Ω
or larger
Содержание INDY7
Страница 1: ...Version 2 3 0 2019 08 16...
Страница 2: ......
Страница 3: ......
Страница 5: ...5...
Страница 8: ......
Страница 12: ......
Страница 15: ......
Страница 128: ...128 05 Programming Now your jointMove setup is complete...
Страница 136: ...136 05 Programming Finally enter the motion name and touch OK Now the frameMove setting is complete...
Страница 144: ...144 05 Programming Now the setting for the blending of frameMove is completed...
Страница 152: ...152 05 Programming Now your home movement setup is complete...
Страница 162: ...162 05 Programming stop It stops program execution No setup is required...
Страница 257: ...257 The commands that can be executed by the digital input signals are listed as follows...
Страница 259: ...259 When the message Do you want to renew it appears touch Yes The message Renewal is complete is displayed Touch OK...
Страница 264: ...264 Robot statuses that can be associated with the digital output signals are listed as follows...
Страница 266: ...266 When the message Do you want to renew it appears touch Yes The message Renewal is complete is displayed Touch OK...
Страница 279: ...279 If you run Conty again the language is changed and shown as follows...
Страница 319: ...319 08 Maintenance and Repair On the next Maintenance Service screen touch Log Touch Sending Log...
Страница 321: ...321 09 Certification 9 Certification 9 1 Machinery Directive...
Страница 322: ...322 09 Certification 9 2 Electromagnetic Compatibility Directive...
Страница 325: ...325 10 Warranty Neuromeka Official Channal Copyright 2016 2022 Neuromeka All rights reserved www neuromeka com...