NTI VEEMUX DVI VIDEO MATRIX SWITCH
22
SerTest- RS232 Interface Test Program
This software allows a user to test the functions of an NTI server switch, matrix switch or Multi-user/Multi-platform switch RS232
interface. The SerTest program is automatically loaded when installing the Matrix Switcher
’
s Control Program as described
above. The SerTest program, located in the NTI program group, generates a main menu with the 4 selections described below:
Main Options
•
Matrix Operations
- send commands to the matrix unit.
•
Ethernet Operations
- set Ethernet connection variables
•
Setup Options
- set COM port, baud rate, and unit address
•
About SerTest
- display the program version
Matrix Operations
Key
Selection
Description
1)
Connect Video Output/User to an Input/CPU
- connect an output to an input
2)
Connect All Video Outputs/Users to an Input/CPU
- connect all outputs to an input
3)
Connect Audio Output/User to an Input/CPU
- connect an output to an input (audio ports only)
4)
Connect All Audio Outputs/Users to an Input
- connect all outputs to an input (audio ports only)
5)
Change Mute Status for Audio Output/User
- mute or un-mute the Audio port output
6)
Change Volume for Audio Output/User
- change Audio port output volume
7)
Read Connection for Video Output/User
-read the connection of a specific video output
8)
Read Connection for Audio Output/User
-read the connection of a specific audio output
9)
Read Mute and Volume for Audio Output/User
- read the volume and the mute status of the specified output
(audio ports only)
a)
Save I/O Connections into Unit Memory
-save the connections into switch memory bank
b)
Restore I/O Connections from Unit Memory
-restore the connections from switch memory bank
c)
Change All Units Baud Rate (9600/COM1:)
-change RS-232 Baud rate of all switches
-the current baud rate and serial port are displayed in
parentheses
d)
Reset Unit
- send a reset command to the switch
- the current unit address is displayed in parentheses
e)
Reset All Units
- send an internal reset command to all switches
f)
Read Unit Size
- read the switch size (number of inputs and outputs)
g)
Read Unit Version/Revision String
-read a string containing the switch version, type, and size
h)
Save All Units I/O Connections into Units Memory
-save the connections into switch memory bank, command for all
switches
i)
Restore All Units I/O Connections from Units Memory
-restore the connections from switch memory bank, command for
all switches
Grayed keys are
for models with audio support
Ethernet Operations
Key
Selection
Description
1)
Set Unit IP Address
- enter the desired IP address in xxx.xxx.xxx.xxx format
- number of digits is minimum 1 and maximum 3 for each field. Leading zeroes are
accepted
2)
Set Unit Subnet Mask
- enter the desired IP address in xxx.xxx.xxx.xxx format
- number of digits is minimum 1 and maximum 3 for each field. Leading zeroes are
accepted
3)
Set Unit Default Gateway
- enter the desired default gateway
- number of digits is minimum 1 and maximum 3 for each field. Leading zeroes are
accepted
4)
Set Unit Website Timeout
- set the website timeout; timeout = numeric string of timeout in seconds
- Values: 60, 300, 600, 900, 1800, 3600, 7200, 18000, 28800 0 = no timeout
5)
Read Unit IP Address
- read the unit IP address in xxx.xxx.xxx.xxx format
6)
Read Unit Subnet Mask
- read the unit subnet mask in xxx.xxx.xxx.xxx format
7)
Read Unit Default Gateway
- read the unit default gateway in xxx.xxx.xxx.xxx format
8)
Read Unit Website Timeout
- read the current website timeout period in seconds
- Values: 60, 300, 600, 900, 1800, 3600, 7200, 18000, 28800 0 = no timeout