NTI VEEMUX DVI VIDEO MATRIX SWITCH
24
ETHERNET CONTROL
Telnet Interface-Port 2000
The Telnet Interface enables the user to control the switch using telnet client through an Ethernet connection. The telnet server
listens on ports 2000 and 2005. Port 2000 is for an operator telnet session while port 2005 (must be enabled) is intended for a
software control type session (see page 26). For operator telnet control using the telnet interface and the current IP address,
type the following in a command shell:
telnet 192.168.1.30 2000
The VEEMUX will prompt the user for a password. The user must enter the password followed by <Enter>.
The factory default password is
"nti".
With a proper password sent the VEEMUX will respond with:
Password Successful
Connection Established
The commands below are now available.
Telnet Interface- Port 2000 Commands
C
ommand
Reply
Description
H(elp) or
h(elp)
Displays the list of commands
Help
CS nn,mm
*<CR>
Connect One input nn To output mm
CA nn
*<CR>
Connect All Outputs To Input nn
RO mm
*<CR>nn<CR>
Read Connection For Output.
Returns the number of the input nn connected to output mm
CC nn
*<CR>nn<CR>
Save Matrix Connections Into Memory Bank nn
nn should be between 00 and 99
RC nn
*<CR>nn<CR>
Restore Matrix Connections From Memory Bank nn
nn should be between 00 and 99
CB nn
*<CR>
Change baud rate of serial line, nn=12(00),24(00),48(00),96(00)
Factory default is 9600.
RV 00
*<CR>string<CR>
Read NTI Version String
RU
*<CR>nn,mm<CR>
Read Unit Size
Returns the number of inputs nn and the number of outputs mm
RS *<CR>
Reset
Unit
AS nn,mm
*<CR>
Connect audio input nn to output mm
AA nn
*<CR>
Connect audio input nn to all outputs
AO mm
*<CR>mm<CR>
Read audio connection for output mm
AM nn,mu
*<CR>
Set mute state for output nn
mu(te State) = (00=UNMUTE, 01=MUTE)
AV mm,vv
*<CR>
Set volume level for output mm
vv is a value between 00 to 99 (see chart page 21)
AR nn
*<CR>MU,VV<CR>
Read mute, volume for output nn
MU is 00 if the port is UNMUTED, MU is 01 if the port is MUTED.
VV is a value between 00 to 99 (see chart page 21)
Ss nn,dwt
*<CR>
Set value of Scan Mode dwell time (see page 9) for specific Output
(nn)
dwt = 000-255 (seconds) 000= disable Scan Mode
Содержание VEEMUX SM-nXm-DVI-LCD