Managed Switch CLI Manual, Release 8.0.3
Switching Commands
3-172
v1.0, July 2010
multiplier on the transmit interval that sets the TTL in local data LLDPDUs. The multiplier range
is 2-10. The
<reinit-seconds>
is the delay before re-initialization, and the range is 1-0
seconds.
no lldp timers
Use this command to return any or all timing parameters for local data transmission on ports
enabled for LLDP to the default values.
lldp transmit-tlv
Use this command to specify which optional type length values (TLVs) in the 802.1AB basic
management set are transmitted in the LLDPDUs. Use
sys-name
to transmit the system name
TLV. To configure the system name, see
“snmp-server” on page 10-41
. Use
sys-desc
to transmit
the system description TLV. Use
sys-cap
to transmit the system capabilities TLV. Use
port-
desc
to transmit the port description TLV. To configure the port description, see See
“description” on page 5.
Default
• interval—30 seconds
• hold—4
• reinit—2 seconds
Format
lldp timers
[interval <interval-seconds>] [hold <hold-value>] [reinit
<reinit-seconds>
]
Mode
Global Config
Format
no lldp timers
[interval] [hold] [reinit]
Mode
Global Config
Default
all optional TLVs are included
Format
lldp transmit-tlv
[sys-desc] [sys-name] [sys-cap] [port-desc]
Mode
Interface Config