MultiPro 2000 User Manual 

 

 

 

 

Dear User, 

 

We appreciate your purchase of Netech’s New and 

enhanced Model of MultiPro 2000, Electrical Safety 

Analyzer. For over a quarter of a century Netech is 

dedicated to provide our customers with high quality, 

value added products. 

 

 Properly used, the MultiPro 2000 delivers more 

performance and accuracy than any other Electrical 

Safety Analyzer in its price range. This manual has been 

designed as a tool to help you get the most from your 

MultiPro 2000.  We suggest that you carefully read this 

manual so that you will be able to properly use and 

maintain this product.  We welcome any comments you 

may have that could help us improve the MultiPro 2000 

and this manual. 

 

Netech is recognized as an innovator and manufacturer 

of advanced affordable instruments.  When you buy our 

products we guarantee absolute satisfaction.  Your 

business is important to us and we are dedicated to 

provide you with the best service possible. 

 

We are pleased you selected the MultiPro 2000 to meet 

your needs.  We hope you will consider us again when 

you have a requirement for accurate, reliable, versatile, 

and yet affordable instruments. 

 

Please visit our websiteproduct updates and user manuals. 

 

Sincerely, 

President

 

Содержание 560-110

Страница 1: ...USER MANUAL MultiPro 2000 PN 560 110 110 VAC PN 560 220 220 VAC Advanced Electrical Safety Analyzer Multi Parameter Simulator 110 Toledo Street Farmingdale NY 11735 www NetechCorp us...

Страница 2: ...anual so that you will be able to properly use and maintain this product We welcome any comments you may have that could help us improve the MultiPro 2000 and this manual Netech is recognized as an in...

Страница 3: ...et those specifications when it was shipped from the factory Calibration measurements are traceable to National Institute of Standards and Technology A calibration certificate is included with the uni...

Страница 4: ...improper use Safety Considerations Read all safety information prior to use Do not apply more than the rated input voltage Do not connect a device that exceeds the rated current Do not use the unit a...

Страница 5: ...se Leakage Using External Leads 19 External Leakage Point to Point Measurement 20 Leads Leakage 21 Power Cord Ground Resistance 24 Simulator Function 25 Save and Print Test Results 27 Saving test resu...

Страница 6: ...Analyzer is a measurement device as well as a waveform simulator The Analyzer is capable of saving over 5000 test records and can be uploaded to a PC for printing and record keeping using the softwar...

Страница 7: ...unctions are available ECG Normal Sinus Rhythm NSR Performance SIN SQUARE TRIANGLE PULSE User selectable Amplitude and rate The waveform output is through the 10 color coded ECG snap posts marked RL L...

Страница 8: ...and the operation of the unit Instrument Familiarization Display The Multi Pro 2000 incorporates a vacuum fluorescent display The display ensures high readability even under the lowest ambient light...

Страница 9: ...eads Leakage Function Key Pressing the key enables the LEADS LEAKAGE Menu selections RESISTANCE MEASUREMENT Resistance Measurement key enables the power cord ground wire resistance measurement menu wi...

Страница 10: ...cted using the keypad to energize the test receptacle during leakage measurement functions Menu Functions and Operation The operation of the MultiPro 2000 is Menu driven It is simple and easy to use f...

Страница 11: ...oftware upgrade and other factory settings In addition to the MAIN MENU function dedicated keys are provided for each of the main functions They are described as follows CASE Leakage Case Leakage curr...

Страница 12: ...MultiPro 2000 User Manual 12 OFF Enables the Power the outlet to turn off REVERSE POLARITY Set the outlet to reverse...

Страница 13: ...will perform a series of self tests and momentarily display the model name and the software version followed by the MAIN MENU as shown below Menu Descriptions Before connecting the DUT Device Under Te...

Страница 14: ...f normal polarity will be activated and the unit DUT will turn on Press ESC to go back to the previous Menu INTERNAL MEASUREMENT Menu POL Polarity Check of the Inlet Power From the INTERNAL MEASUREMEN...

Страница 15: ...2000 is capable of storing over 5000 test results in the Non volatile memory and can be uploaded to a PC to save or print the records The Save option is available in all the measurement Menu refer to...

Страница 16: ...ready entered for the unit under test press F4 N0 Note When testing multiple units it is important to change the ID as the test records are saved under this ID number TIME Time re setting Function Pre...

Страница 17: ...Normal Polarity Reverse Polarity Open Neutral OFF Select the desired polarity The Earth leakage measurement is through the internal ground conductor and the external test lead is not required To meas...

Страница 18: ...eature of the MultiPro will select the appropriate range automatically For reading in excess of 100 micro amps the decimal point will not be displayed The user can switch between Reverse and normal Po...

Страница 19: ...e case leakage Enclosure leakage attach the external Kelvin cable to the case conductive surface of the DUT device under test Select the desired polarity and press READ The display will indicate the l...

Страница 20: ...used to measure Leakage current flowing from any conductive surface of the DUT and Earth ground From the MAIN MENU select XTR F3 Key EXTERNAL LEKAGE Menu will be displayed with the prompt to connect t...

Страница 21: ...t patient connections The following two modes of measurement function available as shown in Screen Shot 5 GND Measures current flowing through the leads to ground In this option leakages of individual...

Страница 22: ...an isolated AC voltage equal to or 10 higher is applied to the leads and earth ground The voltage is current limited but it is lethal DO not touch the exposed metal parts of the ECG post or the analyz...

Страница 23: ...WHILE THE PATIENT IS CONNECTED TO A RELATED POWER SYSTEM BRANCH CIRCUIT This test verifies that the isolation system on the device under test is operating properly The following block diagram shows th...

Страница 24: ...e Once Kelvin cable is attached to a suitable ground on the device under test press the READ switch on the front panel the unit will determine the resistance in 3 seconds Ground resistance will be dis...

Страница 25: ...to 4 5 mV Performance Waveform o SINE TRIANGLE SQUARE PULSE o Rates 0 1 to 60 Hz o Amplitudes 0 1 to 4 5 mV Connect the ECG leads to the respective ECG Snap posts If the DUT is off press the Normal Po...

Страница 26: ...the waveform is displayed as shown in Screen Shot 7 The amplitude and rate selection can be done from this Menu Amplitude selection can be achieved by using F1 to F6 keys indicates the additional sele...

Страница 27: ...g F1 Saving test results in the internal memory To save the test result Press F1 from the measurement menu as shown Screen Shot 8 After saving the test results of the DUT s under test it can be upload...

Страница 28: ...The software is compatible with Windows XP and Windows 7 Run the ProComPrintSetup from the CD by double clicking on the ProComPrintSetup exe Follow the on screen instructions When the installation is...

Страница 29: ...ProComPrint Version 1 0 Features The ProComPrint Ver 1 0 included with the unit is a basic version of the optional customizable database version This will earnable the user to quickly connect the Mult...

Страница 30: ...een Select Equipment ID If multiple units are being tested the results of the individual units can be down loaded by selecting the Equipment ID using the v arrow CLR MEMORY This will clear all the sav...

Страница 31: ...as shown below is included in the ProComPrint Ver 1 0 Note Sample Data Sheet can be opened and printed only if a licensed copy of the word is installed in the PC The test results that are saved will b...

Страница 32: ...the Print menu options HEAD Select F1 for uploading a blank header with user editable fields RESULT Select F3 for uploading all saved test results CLR Select F6 for clearing all the records saved in t...

Страница 33: ...Range Auto range 0 to 99 9 100 to 2000 uA Accuracy DC to 100 Hz 1 of the reading 2 uA 100 Hz to 1 kHz 2 of the reading 3 uA 1 kHz to 1 MHz 10 of the reading 10uA Current Range 0 99 9 100 2000 Micro A...

Страница 34: ...um 220 Volt Units PN 560 220 180 VAC to 260 V AC to 130 V 50 Hz to 60 Hz 16 A Maximum Simulator NSR Normal Sinus Rate 30 60 70 80 90 100 120 150 180 210 240 270 and 300 BPM Accuracy 1 1 BPM Amplitude...

Страница 35: ...nnual recalibration Netech recalibration charges are very low compared to the industry standard Any firmware or software update will be done during annual recalibration at no additional cost Field cal...

Страница 36: ...damage instruments Malfunction Please follow these steps for repair or re calibration of your NETECH instrument 1 Obtain an RMA Return Merchandise Authorization by calling Netech Customer Service 1 6...

Страница 37: ...at its factory in Farmingdale New York USA Netech support its products longer than any other manufacturer in this field All Netech Products are manufactured in the USA We are proud to serve the globa...

Страница 38: ...arts and Accessories Part Number Description 560 110 MultiPro 2000 Safety Analyzer 110 V 560 220 MultiPro 2000 Safety Analyzer 220 V 560 503 Test Lead set of two 560 HRD CASE Hard Carrying case 560 55...

Страница 39: ...ity with the above warranty including a detailed explanation of the alleged deficiencies 2 The MULTI PRO 2000 is returned to Netech at the buyer s expenses only after obtaining the proper RMA authoriz...

Отзывы: