NEOMERIS CONTROL DES
Functional description
Build:20211025-094624-9873335NSt
All information and technical data are subject to
change
Page 48
Range:
0 ... 999 s
Default:
0 s
»Reac. Sys.
(Sel.)
Reaction of the system to an alarm-type mes-
sage
Default:
Continue
0 Continue
No shutdown
1 Shutdown
Shutdown with permanent re-
tries
2
Cycl.shut-
down
Shutdown with defined number
of retries
3
Dur. shut-
down
Durable shutdown
6.12.3.2 Analog input (AI)
Flow meter
Water amount per houer.
Input range:
0 ... 32767 l/h
6.12.3.3 Counter (CNT)
Volume
(Num.)
Absolut value of water counter. How match im-
puls were counted.
Range:
0 ... 99999 m³
Default:
0 m³