Neomeris CONTROL DES Скачать руководство пользователя страница 13

NEOMERIS CONTROL DES 

 

Notes and instructions to be 

observed

 

 

 

Build:20211025-094624-9873335NSt

   

All information and technical data are subject to 

change 

Page  6 

 

2.14  Warranty and liability 

Bodily harm and material damage as well as damage to the system itself are excluded from 
warranty and liability claims if they can be traced back to one or more of the following causes:

 

§

 

Incorrect use of the system.

 

§

 

Improper installation, start-up, operation, and maintenance of the 
system.

 

§

 

Operation  of  the  system  with  defective  or  improperly  attached  or 
non-functioning safety devices and safeguards.

 

§

 

Failure to observe the notes in the operation manual with regard to 
transport,  storage,  installation,  start-up,  operation,  and  mainte-
nance of the system.

 

§

 

Unauthorised structural modifications to the system.

 

§

 

Unauthorised changes to the control parameters.

 

§

 

Poor monitoring of system parts prone to wear and tear.

 

§

 

Improperly executed repair work.

 

§

 

Failure to keep, or incompletely kept, maintenance logs.

 

§

 

Disaster situations caused by foreign objects or force majeure.

 

Our General Terms and Conditions apply. 

 

2.15  Copyright   

The manufacturer / supplier retains the copyright to this operation manual. This operation man-
ual is only intended for the owner and their staff. 

 

It contains regulations and notes exempt from any of the following, neither fully nor partially:

 

§

 

Duplication,

 

§

 

Distribution, or

 

§

 

any other form of communication.

 

Contraventions may be prosecuted. 

 

 

Содержание CONTROL DES

Страница 1: ...Manual NEOMERIS CONTROL DES Bleed off process Version 1 12...

Страница 2: ...y products The manufacturer makes no warranty representation or guarantee regarding the suitability of its prod ucts for any particular purpose nor does assume any liability arising out of the applica...

Страница 3: ...energy 5 2 11 Intended use 5 2 12 Unconventional use 5 2 13 Structural modifications to the controller system 5 2 14 Warranty and liability 6 2 15 Copyright 6 3 Delivery scope 7 3 1 Unpacking and chec...

Страница 4: ...Schema 24 5 6 Configuration Jumper 25 6 Functional description 26 6 1 System overview structure 26 6 2 Module MDesalDevice2Ext 27 6 2 1 Info 27 6 2 2 Comment 27 6 2 3 Internal elements of module 28 6...

Страница 5: ...1 Info 45 6 12 2 Comment 45 6 12 3 Internal elements of module 46 6 13 Module MTankAlarms 49 6 13 1 Info 49 6 13 2 Comment 49 6 13 3 Internal elements of module 49 6 14 Module MPumpPuls 51 6 14 1 Inf...

Страница 6: ...64 7 8 Firmware Update 64 7 9 Factory settings 64 7 10 HMI overview 65 8 Anhang 72 8 1 bersicht der Parameter 72 8 2 Maintenance and Repair 82 8 2 1 Maintenance of the Lithium Battery 82 8 2 2 Cleani...

Страница 7: ...NEOMERIS CONTROL DES Build 20211025 094624 9873335NSt All information and technical data are subject to change...

Страница 8: ...to life and limb of the user or of third parties and may also cause damage to the system and other property Only use the system for its intended purpose and if all of its safety equipment is in perfec...

Страница 9: ...ive measures A specialist is required to comply with the relevant technical rules Staff in training may only work on the system whilst under the su pervision of experienced staff 1 5 Warnings in this...

Страница 10: ...installing or connecting and or disconnecting the device to the mains Secure the system against unauthorised re start Only connect the device to a mains voltage as specified on the rat ing plate Foll...

Страница 11: ...te of use In addition to the operating manual provide and observe generally applicable and local regulations on accident prevention and envi ronmental protection Always make sure that all of the safet...

Страница 12: ...from such use Intended use also includes Observing all of the instructions provided in this operation manual and Adhering to the specified inspections and maintenance intervals 2 12 Unconventional use...

Страница 13: ...in the operation manual with regard to transport storage installation start up operation and mainte nance of the system Unauthorised structural modifications to the system Unauthorised changes to the...

Страница 14: ...rators postal services lorry companies other carriers hauliers stockists customs and port authorities to inspect the damage together Have them accept their liability in writing specifically a In case...

Страница 15: ...es Complete System Base 1 Base System Cable 10 Pins no 3V3 Bus Cable 1 Connection Cable Ribbon Cable CPU Display CPU Board Unit 1 CPU Board Unit Housing Housing 1 Housing Cable Gland M12 1 Gland M12 C...

Страница 16: ...5 with PT100 stainless steel V4A 1 4571 integral thread 3 4 without cable Range of applica tion 0 2000 S cm max 130 C Adaption Required accessories cable customer supplied Item Number 310126 Identifi...

Страница 17: ...ing display and operating components Display Type Graphic Display Display Size 2 8 Inch Display Resolution 128x64 Pixel monochrome Backlight colored backlight RGB LED Operation Elements 4 foil keys Op...

Страница 18: ...olated contact npn switching against GND Low Volt 1MOhm High Volt 100Ohm Input Current 5mA 24V Component Remark Input is supplied internal Identifier System enable Information Type Input for ext isola...

Страница 19: ...ng max Switching Volt 250V AC max Switching Cur 10A AC Contact 16A max Perm Current 5A AC nom Cycles see datasheet Component Schrack RT33L024 Remark with snubber Identifier Dosing Pump Information Dos...

Страница 20: ...e for cell constant K 0 01 10 Remark Identifier Cond Probe inductive Information Type Current Input Range 0 20mA 2 3 wire Input Resistance 175 Ohm Resolution 10Bit Accuracy 0 5 Linearity 0 2 Filter Li...

Страница 21: ...pulse inputs counter inputs Identifier Flow meter Information Type Impuls Digital input universal 2 3 wire Threshold 0 6 1V Input Circuit n switching Sensitivity rising slope Gate Time Frequ Mode 10ms...

Страница 22: ...are subject to change Page 15 Type Standard Specification EC Declaration of Conformity CE Mark conform EMC Directive EMV 2014 30 EG conform Low Voltage Directive 2014 35 EG conform Standard EN 61000 6...

Страница 23: ...NEOMERIS CONTROL DES Specifications Build 20211025 094624 9873335NSt All information and technical data are subject to change Page 16 4 3 Views and dimensional drawings 4 3 1 Front film layout...

Страница 24: ...ecifications Build 20211025 094624 9873335NSt All information and technical data are subject to change Page 17 4 3 2 Housing Bottom and Drill Pattern For mounting use the following pattern measurement...

Страница 25: ...ler in a well lit and easily accessible place so that operating and display elements are eas ily visible and accessible Do not place the controller on surfaces with high vibration e g cooling tower wa...

Страница 26: ...top gap between housing and wall and tighten almost all the way Insert bottom screws into the bottom gap between housing and wall and tighten them plus the top screws all the way Close housing lid 5 2...

Страница 27: ...on terminal assignment can be found in chapter 5 4 4 To connect the cables please proceed as follows Pass the cable through one of the cable glands on the underside of the housing into the housing in...

Страница 28: ...20211025 094624 9873335NSt All information and technical data are subject to change Page 21 5 4 Terminal connection 5 4 1 Component Inside view below The following diagram indicates the major operati...

Страница 29: ...o250 2 5mm Cage Terminal 13 up to 0 5mm or 0 8mm 50V 1A eB2 TB2 Wago250 3 5mm Cage Terminal 2 up to 1 5mm 250V 8A 5 4 4 Terminal assignments Te block Te no Te id Type Usage Function PE Protective Eart...

Страница 30: ...ystem enable eB1 TB4 23 GND Ground DosProp 1 Tank empty eB1 TB4 24 IN Input for ext floating contact DosProp 1 Tank empty eB1 TB4 25 IN Input for ext floating contact TimeDosing Tank empty eB1 TB4 26...

Страница 31: ...11025 094624 9873335NSt All information and technical data are subject to change Page 24 5 5 Input Output Schema The following diagram shows the adaption of the control unit To avoid overlapping some...

Страница 32: ...rox 1000 S cm From the list below option B would be suitable Jumper 1 must be plugged in and the Meas Ampl Gain set to 10 in the Conductivity Sensor menu so that a measurement range up to 1000 S cm ca...

Страница 33: ...valve Blowd flow MFlowMeter2 Flow calculation Prop dosing 1 MDosProp Proportional dosing Tank prop Dos 1 MTankAlarms Tank with chemicals Alarm empty MAlarm Sends alarm if the tank is empty Alarm full...

Страница 34: ...onal parts MDosProp Volume proportional dosage This module controls the proportional dosage MDosTime Time dosage This module controls the timed dosing MUnlock Unlock plant This module manages the rele...

Страница 35: ...pulse control MStartData Time Dosing Record This module creates the schedule for time dosing MAlarmMgrDOs Alarm Manager This module collects and detects information alerts and alarms of each module M...

Страница 36: ...alve remains open until the setpoint of the process water conductivity falls below the set hysteresis parameter hysteresis In addition the conductivity of the process water can be reduced by pre desal...

Страница 37: ...0 Range 0 5000 S cm Default 2500 S cm Hysteresis Num Conductivity hysteresis for the desalination start Range 0 5000 S cm Default 20 S cm Pre Bleed start Num Reduction of the conductivity threshold be...

Страница 38: ...output pulses the amount of chemicals is determined Then according to the settings made the desired amount of chemicals is added by the metering pump Due to the lockdown parameter time lock after a t...

Страница 39: ...to change Page 32 Range 0 00 9 99 s Default 0 25 s High duration Num Period duration of proportional dosing output impuls Range 0 00 9 99 s Default 0 25 s Pulse limit Num Limit of stored impulses Rang...

Страница 40: ...e can also be set The time dosing has the following operating modes Automatic compares the current time with the set start time and if appropriate starts the time metering On It is dosed permanently u...

Страница 41: ...tional description Build 20211025 094624 9873335NSt All information and technical data are subject to change Page 34 Range 0 999 min Default 15 min Total Time Num Max possible dosing time per day Rang...

Страница 42: ...ion The contact type can be freely selected When occupied active closing the input activates the operation When occu pied inactive opening the input will activate the operation 6 6 3 Internal elements...

Страница 43: ...2000 S cm Accordingly at 0 S cm the output is approximately 0mA and at 2000 S cm approximately 20mA As a result e g 500 S cm is approx 5mA 1000 S cm is approx 10mA 1500 S cm is approx 15mA etc With a...

Страница 44: ...NEOMERIS CONTROL DES Functional description Build 20211025 094624 9873335NSt All information and technical data are subject to change Page 37 Output range 0 00 20 00 mA...

Страница 45: ...5NSt All information and technical data are subject to change Page 38 6 8 Module MOpTime 6 8 1 Info Operating Time 6 8 2 Comment Counts the operating hours of the plant and stores them in permanent me...

Страница 46: ...ump is always energized as long as the desalination is active or the desalination mode is ei ther process controlled or on 6 9 3 Internal elements of module 6 9 3 1 Parameters Switch On Delay Num Dela...

Страница 47: ...nsated to the reference value 25 degrees celsius 3 Not compensated Submodules MTemperature Measures the temperature 6 10 3 Internal elements of module 6 10 3 1 Parameters Reference Num Reference tempe...

Страница 48: ...m threshold Range 0 5000 S cm Default 0 S cm Hysther Alarm Num Hysteresis used as from threshold Range 0 5000 S cm Default 0 S cm Prio Warn Num Set warning priority Range 0 99 Default 50 Prio Alarm Nu...

Страница 49: ...ata are subject to change Page 42 6 10 3 2 Analog input AI Cond conductive eB2 11 PE 12 LF 13 0V Conductance Input 1 Input range 0 5000 S cm Cond inductive eB2 5 24V 6 D1 7 0V Analog Input 1 with supp...

Страница 50: ...in Alarm Num Alarm low limit Range 0 0 99 9 C Default 3 0 C Max Warn Num Warning high limit Range 0 0 99 9 C Default 60 0 C Max Alarm Num Alarm high limit Range 0 0 99 9 C Default 80 0 C Hysther Warn...

Страница 51: ...ge 44 Reac Sys Sel Reaction of the system to an alarm type mes sage Default Continue 0 Continue No shutdown 1 Shutdown Shutdown with permanent re tries 2 Cycl shut down Shutdown with defined number of...

Страница 52: ...he hardware used There are three measurement methods Automatic Automatically selects between pulse counter measurement and pulse length measure ment based on the frequency of measurement errors that o...

Страница 53: ...2 times the lowest operating frequency must be avoided in which case the measurement results are not reliable Debouncing is only relevant for pulse length measurement Pulses that are consecutively re...

Страница 54: ...um Warning low limit Range 0 32767 l h Default 0 l h Min Alarm Num Alarm low limit Range 0 32767 l h Default 0 l h Max Warn Num Warning high limit Range 0 32767 l h Default 900 l h Max Alarm Num Alarm...

Страница 55: ...to an alarm type mes sage Default Continue 0 Continue No shutdown 1 Shutdown Shutdown with permanent re tries 2 Cycl shut down Shutdown with defined number of retries 3 Dur shut down Durable shutdown...

Страница 56: ...vent false readings from moving liquid The parameter Tank type can be used to set whether the tank has an overflow or not 6 13 3 Internal elements of module 6 13 3 1 Parameters Contact Up Sel Kind of...

Страница 57: ...NEOMERIS CONTROL DES Functional description Build 20211025 094624 9873335NSt All information and technical data are subject to change Page 50...

Страница 58: ...dosing pump in conjunction with a flow meter as the flow meter generates pulses that can be processed this way 6 14 3 Internal elements of module 6 14 3 1 Parameters Contact Type Sel Kind of contact I...

Страница 59: ...ding to the time metering This record is compared to the current time If the set start time matches the current time and the set weekdays are the same as the current day of the week a time dosing is s...

Страница 60: ...rmally Shutdown with permanent retries The system reports the error and stops the process as long as the condition of the alarm is present When the alarm is cleared the process restarts Shutdown with...

Страница 61: ...t der Aufzeichnung 3 ID der Aufnahme normalerweise D f r zyklische Aufnahme A A f r Alarm 4 Informationen z B Alarmtext 6 17 3 Internal elements of module 6 17 3 1 Parameters Record Interval Num Time...

Страница 62: ...NEOMERIS CONTROL DES Functional description Build 20211025 094624 9873335NSt All information and technical data are subject to change Page 55...

Страница 63: ...s The user interfaces is arranged as follows 7 2 Navigation and Programming 7 2 1 General information Use keyboard and display for programming the control system Incorrect programming may lead to a fa...

Страница 64: ...ic reset If no keys have been pressed for 5 minutes the system will automatically quit the menu view und return to the main display 7 2 2 Passwords The device has 3 password levels with the following...

Страница 65: ...isting in this present control unit It is possible that several configuration menus exist There could be a configuration menu in the main menu which shuts off all modules Similarly a configuration men...

Страница 66: ...menu Sample of a selection mask Example tank level Our tank has a Normally Open NO contact as a water level sensor at the top of the tank This means that if the contact type is set to NO the tank wil...

Страница 67: ...ociated sensor must be possible There fore prior to LF calibration perform a temperature calibration For the temperature compensation to work the temperature sensor must capture the current process wa...

Страница 68: ...ue exit the mask with Enter The new assignment Act 25 4 C to the converter value 00583 is displayed Calibration takes place in the following steps 1 Specifying a reference value to the sensor In this...

Страница 69: ...NSt All information and technical data are subject to change Page 62 7 5 2 Analog Output Similar to the input calibration the output calibration takes place In the channel list it is possible to force...

Страница 70: ...ct one of the digital inputs or outputs whose name and status are displayed in verbal form The manipulation off on is done via the Enter key This feature gives the technician the opportunity to test t...

Страница 71: ...s its backlight depending on the message Green there are no messages Blue information is available Yellow there are warnings Red there are alarms The numbers indicate the number of Info Warnings Alarm...

Страница 72: ...5 094624 9873335NSt All information and technical data are subject to change Page 65 7 10 HMI overview Logo Version Main View Start Stop Main Menu Messages Settings Bleed off Conductivity Sensor Limit...

Страница 73: ...DES Operation Build 20211025 094624 9873335NSt All information and technical data are subject to change Page 66 Add Flow Limits Prop dosing 1 Tank Time Dos 1 Dosing Pump 1 Time Dosing 1 Dosing Valve 1...

Страница 74: ...ation Build 20211025 094624 9873335NSt All information and technical data are subject to change Page 67 System enable Operating Signal Blowdown Analog Output Circulation Pump Data Transfer Data Acquis...

Страница 75: ...20211025 094624 9873335NSt All information and technical data are subject to change Page 68 Settings Prot Show Protocol Protocol data Service NEOMERIS CONTROL DES NEOMERIS CONTROL DES UniqueID NEOMER...

Страница 76: ...L DES Operation Build 20211025 094624 9873335NSt All information and technical data are subject to change Page 69 Diagnosis Calibration Cyclic Retry Configuration Configuration Configuration Tank Time...

Страница 77: ...CONTROL DES Operation Build 20211025 094624 9873335NSt All information and technical data are subject to change Page 70 Dosing Pump 1 Configuration Dosing Valve 1 Factory Settings Main View Main View...

Страница 78: ...NEOMERIS CONTROL DES Operation Build 20211025 094624 9873335NSt All information and technical data are subject to change Page 71 Main View Main View...

Страница 79: ...MERIS CONTROL DES Device Data Transfer A character to separate the data from each other Default 0 TAB 1 2 Record Interval Num NEOMERIS CONTROL DES Device Data Ac quisition Time interval at which the r...

Страница 80: ...osing Range 0 5000 S cm Default 800 S cm Durat prebleed Num NEOMERIS CONTROL DES Device Bleed off Max duration of the pre desalination Range 0 999 min Default 60 min Reference Num NEOMERIS CONTROL DES...

Страница 81: ...Default 0 S cm Hysther Alarm Num NEOMERIS CONTROL DES Device Bleed off Conductivity Sensor Hysteresis used as from threshold Range 0 5000 S cm Default 0 S cm Prio Warn Num NEOMERIS CONTROL DES Device...

Страница 82: ...S CONTROL DES Device Bleed off Conductivity Sensor Temp Sensor Hysteresis used as from threshold Range 0 0 99 9 C Default 5 0 C Prio Warn Num NEOMERIS CONTROL DES Device Bleed off Conductivity Sensor...

Страница 83: ...Num NEOMERIS CONTROL DES Device Bleed off Blowd flow Minimal working reach of the flow Range 1 32767 l h Default 400 l h Maxim flow Num NEOMERIS CONTROL DES Device Bleed off Blowd flow Maximal working...

Страница 84: ...50 Prio Alarm Num NEOMERIS CONTROL DES Device Bleed off Blowd flow Set alarm priority Range 0 99 Default 20 Delay Warn Num NEOMERIS CONTROL DES Device Bleed off Blowd flow Delay of warning triggering...

Страница 85: ...ls Contact Up Sel NEOMERIS CONTROL DES Device Prop dosing 1 Tank prop Dos 1 Kind of contact used n used Default occupied active 0 occupied ac tive 1 not occu pied active Contact Low Sel NEOMERIS CONTR...

Страница 86: ...Imp avail Imp n avail Default active Impulse available 0 active Impulse available 1 active Impulse not available Time Dos mode Sel NEOMERIS CONTROL DES Device Time Dosing 1 Mode of time proportional d...

Страница 87: ...TROL DES Device Operat ing Signal Kind of contact pulled released Default active pulled 0 active pulled 1 active drop off Range Sel NEOMERIS CONTROL DES Device Blow down Analog Output Range of current...

Страница 88: ...NEOMERIS CONTROL DES Appendix Build 20211025 094624 9873335NSt All information and technical data are subject to change Page 81 1 active not en ergized...

Страница 89: ...Lithium battery is only used to supply the real time clock the parameters settings calibration will be stored without battery A used battery has to be replaced by the same type Therefore the control u...

Страница 90: ...software update file name must be Cortex bin from the PC to the new shown removable storage Wait till the copy process is finished 7 Switch off the control unit 8 Remove the boot jumper 9 Switch on t...

Страница 91: ...th Windows 7 and Windows 8 a corresponding driver must be installed which is available for download with installation instructions on the previously mentioned web address Starting with Windows 10 no s...

Страница 92: ...NEOMERIS CONTROL DES Appendix Build 20211025 094624 9873335NSt All information and technical data are subject to change Page 85 8 4 4 View of the Main Screen...

Страница 93: ...28x64 in ka liset_ai hinzugef gt Leitf higkeit wird korrekt zur ck nominiert NEOMERIS CONTROL DES Bugfix1 2019 04 11 SWappl improvement tested NSt new customer requirement Module ab anschaltbar gemach...

Страница 94: ...Bugfix tested NSt The area of the analog output was not saved be cause the element was a SYS and not a PAR Element type changed from SYS to PAR The range of the analog output is saved correctly NEOME...

Страница 95: ...NEOMERIS CONTROL DES Appendix Build 20211025 094624 9873335NSt All information and technical data are subject to change Page 88 8 6 EC Declaration of Conformity See next page...

Отзывы: