Start
N
N-1
N-2
③
②
Camera control register setting :
FrameTriggerEnable= 1、 FrameTriggerConfig= 0
Stop
①
Acquisition
1. After setting AcquisitionStart, a Frame signal is generate according to the
external Frame Trigger signal. Frames continue to be sent while the electrical
level of the external frame trigger is “High”.
2. The frame start timing is determined by the position of the first pixel of the line
internally to the camera. This is controlled automatically in the case of Free Run
exposure mode, or by the user in the case of External Trigger exposure mode.
3. When the external frame trigger signal becomes “Low”, frame transmission stops,
after the currently transmitting frame has been completed.
EXT_FRAME
FRAME
1
2
④
Camera control register setting :
FrameTriggerEnable= 1、 FrameTriggerConfig= 0
3
1
2
3
4
1
2
3
4
Acquisition
Start
Stop
4
⑤
4. While AcquisitionStart is valid, the external frame trigger can be used for control.
At this time, set the timeout function of your application appropriately.
5. On AcquisitionStop, packet transmission is stopped.