NED
SU2025GIG
UME-0025-02
34
EXT_TRIGGER
LINE
1
2
①
②
Camera control register setting :
TriggerMode= 1、 LineTriggerMaskTimeR= 10
Internal_Trigger
Acquisition
Start
3
10μs
1. On the rising edge of the external trigger signal, a trigger signal is generated
internally in the camera.
2. During the 10µs set in the register, signal transitions are ignored (masked).