LineTriggerConfig
0x0000A228
0
External Trigger Invert Disable
External Trigger Invert Enable
1
LineTriggerMaskTimeR
0x0000A22C
0 ~ 1000000
External Trigger Signal(Rising)
Chatter prevention function
LineTriggerMaskTimeF
0x0000A230
0 ~ 1000000
External Trigger Signal (Falling)
Chatter prevention function
FrameTriggerMaskTimeR
0x0000A234
0 ~ 1000000
Frame Trigger Signal (Rising)
Chatter prevention function
FrameTriggerMaskTimeF
0x0000A238
0 ~ 1000000
Frame Trigger Signal (Falling)
Chatter prevention function
UserSet_ResetToFactory
Default
0x0000A0B8
Reset to Factory Settings (See 5.14.1)
UserSet_Load
0x0000A0BC
Load from Memory
UserSet_Save
0x0000A0C0
Save to Memory
NB) Make sure to only adjust the below registers while image acquisition is stopped. If the frame size
is changed while acquiring images, a malfunction will occur on the acquisition side.
・
OffsetX
・
Width
・
Height
・
PixelFormat
・
UserSet_ResetToFactoryDefault
・
UserSet_Load