CHAPTER 7 TIMER/COUNTER FUNCTION (REAL-TIME PULSE UNIT)
Figure 7-21. Example of TM3 Capture Operation (when ES301 = 0, ES300 = 0, CMS3 = 0, CE3 = 1)
7.7.6 Compare operation
When the TM3 register is set as a compare register, the capture/compare register (CC3) performs a comparison
between the value in a compare register and the count value of TM3.
When the count value of TM3 coincides with the value of the compare register programmed in advance, clear and
start of TM3 is performed, and interrupt request signal INTCC3 is generated at the same time.
D0
D4
TM3
INTP30
CC3 trigger
CP3 trigger
CC3
CP3
INTCC3
0H
D0
D2
D4
D3
D1
D1
D3
D2
Содержание V854 UPD703006