CHAPTER 8 SERIAL INTERFACE FUNCTION
(5) Stop condition
The stop condition is generated when the SDA pin changes from low level to high level while the SCL pin is
high level.
The stop condition is a signal which the master outputs to the slave when a serial transfer has ended. The
slave is provided with the hardware to detect the stop condition.
Figure 8-19. Stop Condition
The stop condition is generated by setting (to 1) bit 0 (SPT) of the IICC control register (IICC). When the stop
condition is detected, bit 0 (SPD) of the IICC status register (IICS) is set (1). When bit 4 (SPIE) of IICC is
set (1), INTIIC is generated.
SCL
H
SDA