User’s Manual U11969EJ3V0UM00
187
CHAPTER 7 TIMER/COUNTER FUNCTION (REAL-TIME PULSE UNIT)
7.5.6 Compare operation
A comparison between the value in a compare register with the count values of TM1 can be performed.
When the count values of TM1 coincide with the value of the compare register programmed in advance, INTCM10
coinciding with CM10 is generated as a trigger of the real time output port. An interrupt request signal INTCM can
be generated at the same time.
Table 7-5. Interrupt Request Signal from 24-Bit Compare Register
Compare Register
Interrupt Request
Compare Match Trigger
CM10/CM10L
INTCM10
Real time output port
CM11/CM11L
INTCM11
—
Figure 7-15. Example of Compare Operation
Remark
Note that the coincidence signal INTCM is generated immediately after TM1 is incremented as shown
above.
Count clock
Timer 1
CM10
Coincidence detected
INTCM10
n – 1
n
n + 1
n
TM1
Содержание V854 UPD703006
Страница 2: ...2 User s Manual U11969EJ3V0UM00 MEMO ...
Страница 22: ...22 User s Manual U11969EJ3V0UM00 MEMO ...
Страница 80: ...80 User s Manual U11969EJ3V0UM00 MEMO ...
Страница 134: ...134 User s Manual U11969EJ3V0UM00 MEMO ...
Страница 156: ...156 User s Manual U11969EJ3V0UM00 MEMO ...
Страница 294: ...294 User s Manual U11969EJ3V0UM00 MEMO ...
Страница 320: ...320 User s Manual U11969EJ3V0UM00 MEMO ...
Страница 324: ...324 User s Manual U11969EJ3V0UM00 MEMO ...
Страница 336: ...336 User s Manual U11969EJ3V0UM00 MEMO ...
Страница 376: ...376 User s Manual U11969EJ3V0UM00 MEMO ...
Страница 382: ...382 User s Manual U11969EJ3V0UM00 MEMO ...
Страница 394: ...394 User s Manual U11969EJ3V0UM00 MEMO ...
Страница 396: ...396 User s Manual U11969EJ3V0UM00 MEMO ...