ND-70348 (E)
CHAPTER 4
Page 665
Revision 3.0
ASYDN
SYSTEM
DATA
TYPE
(SYS)
SYSTEM
DATA
INDEX
(INDEX)
0–1535
DATA
(DATA)
00
–
FF
(Hex)
BIT
CORRESPONDING
DATA
SYSTEM DATA CONTENTS
(MDATA)
DATA
0/1
BIT
1
70
0
b
0
Not used
0
b
1
0
b
2
0
b
3
b
4
One digit dialing instead of SHF (DP TEL only)
0/1 = Not Required/Required
0
b
5
Not used
b
6
Announcement Trunks used for Delay Announcement -
UCD service (for Netfusing Service)
0/1 = Common/Per UCD group
b
7
Send Warning Tone to interrupted parties when Executive
Right of Way service is in operation
0/1 = Required/Not Required
71
b
0
Call Back Automatic Cancel Timer
Value = TX (X1H to XFH)
×
MTC (3.5 minutes)
This Timer can be assigned a value from 3.5 minutes to
52.5 minutes.
b
1
b
2
b
3
0
b
4
Not used
0
b
5
0
b
6
b
7
Enable Call Back Automatic Cancel Timer
0/1 = No/Yes
72
00
Not used
73
00
Not used