ND-70348 (E)
CHAPTER 4
Page 299
Revision 3.0
ATDP
3. Data Entry Instructions
♦
Tandem Switching
TANDEM/
OUTGOING
CONNECTION
(TDM/OG)
DAY/NIGHT
MODE
(DAY/NIGHT)
INCOMING
ROUTE
NUMBER
(ICRT)
OUTGOING
ROUTE
NUMBER
(OGRT)
DESTINATION (AREA) CODE
(DC)
MAX. 11 DIGITS
NECESSARY
DIGIT
(NND)
1-12
RESTRICTION
DATA
(TDI)
0-3
T = Tandem Connection
O = Outgoing Connection
TDM/OG
DAY/NIGHT
D = Day Mode
N = Night Mode
TDI
Restriction Data
0 = Connection is Restricted
1 = Connection is Allowed
2 = 3/6 Digit Toll Restriction
3 = C.O. Operator Call (9+0)
When assigning DC, the digits including
the access code must be assigned.
NND
This parameter is
available only when
TDI=2
NND
This parameter is
available only when
TDI=2
T
TANDEM/
OUTGOING
CONNECTION
(TDM/OG)
DAY/NIGHT
MODE
(DAY/NIGHT)
RESTRICTION
CLASS
(RSC)
0-15
OUTGOING
ROUTE
NUMBER
(OGRT)
DESTINATION (AREA) CODE
(DC)
MAX. 11 DIGITS
NECESSARY
DIGIT
(NND)
1-12
RESTRICTION
DATA
(TDI)
0-3
O
♦
Outgoing Connection
T = Tandem Connection
O = Outgoing Connection
TDM/OG
DAY/NIGHT
D = Day Mode
N = Night Mode
TDI
0 = Connection is Restricted
1 = Connection is Allowed
2 = 3/6 Digit Toll Restriction
3 = C.O. Operator Call (9+0)
When assigning DC, the digits including
the access code must be assigned.
Refer to the ARSC command.