ND-70348 (E)
CHAPTER 4
Page 182
Revision 3.0
ASYD
SYSTEM
DATA
TYPE
(SYS)
SYSTEM
DATA
INDEX
(INDEX)
0 – 511
DATA
(DATA)
00 – FF
(Hex)
BIT
CORRESPONDING
DATA
SYSTEM DATA CONTENTS
DATA
0/1
BIT
1
401
b
0
Miscellaneous Timer Counter
(MTC) is to be assigned a value from
0 Hex to F Hex (0-15).
No Answer Timer for Automatic
Idle Return.
Timer Value Setting is MTC
×
2 sec.
Note:
When MTC is 0 Hex, de-
fault data is automatical-
ly set to 0 ~ 2 sec.
b
1
b
2
b
3
0
b
4
Not used
b
5
Call Transfer ID, Call Forwarding ID
0/1 = Invalid/Valid
b
6
SMDR Output Method
0/1 = Free wheel/Output on receipt of send request from external
equipment
0
b
7
Not used
402
b
0
Miscellaneous Timer Counter
(MTC) is to be assigned a value from
0 Hex to F Hex (0-15).
Station Release Timer after receiv-
ing CLR FWD signal from the
Local/Toll trunk (for Russia)
.
Timer Value Setting is MTC
×
TC.
Note:
When this data is 00 Hex,
default data is automati-
cally set to 30 sec.
b
1
b
2
b
3
b
4
Timer Class (TC) is to be assigned
one of the following values:
b
5
b
6
0
b
7
Not used
403
00
Not used
416
00
Not used
417
b
0
Recall Ringer Pattern for CALL BACK [C-1], CALL WAITING-ORIGI-
NATING [C-31], and OUTGOING TRUNK QUEUING [O-2].
0/1 = Ringer Pattern 5/Ringer Pattern 1
b
3
~b
7
Not used
418
00
Not used
431
00
Not used
b
6
0
0
0
0
b
5
0
0
1
1
b
4
0
1
0
1
= –
= –
= –
= –
b
6
1
1
1
1
b
5
0
0
1
1
b
4
0
1
0
1
= 30 sec.