ND-70348 (E)
CHAPTER 4
Page 463
Revision 3.0
AMAT
AMAT: Assignment of Master Attendant Data
1. General
When more than one Attendant Console has been installed for one tenant, this command assigns a Master Con-
sole for controlling the Day/Night function of all the Attendant Consoles on a tenant basis.
2. Precautions
1.
This assignment is necessary when Day/Night changeover is controlled by a Master Console (the ASYD
command, SYS 2, INDEX 2, bit2=1 & bit3=0).
2.
If this Master Console is placed in the Night mode, all incoming calls will be directed to TAS or a Night
Connection Fixed station.
3.
The applicable tenant number (TN) range is designated by the ASYD command, SYS 1, INDEX 8.
4.
The maximum number of Attendant Consoles (Attendant Consoles) should be assigned by the ASYD com-
mand, SYS 1, INDEX 9.
3. Data Entry Instructions
Enter the desired Attendant Console to be operated as a master.
1=Attendant Console which is assigned as RT=901(ATT) by the ATRK command. (MATN)
2=Attendant Console which is assigned as RT=915 (NATT) by the ATRK command. (NATN)
MODE
(MODE)
1/2
TENANT NUMBER
(TN)
ATTENDANT NUMBER (ATN)
REMARKS
Enter desired Attendant Console number assigned by the ATRK command.
ATN