ND-70348 (E)
CHAPTER 4
Page 537
Revision 3.0
AUADL
3. Data Entry Instructions
NUMBER OF
ANNOUNCEMENT
TRUNK
(CNT)
1-8
CONTROLLING STATION
ANNOUNCEMENT
TRUNK
UGN and TELN
DLYT
Enter the delay timer value in second with a range of 0-
30 seconds. (2 seconds increments)
UGN is fixed to "1".
Enter the TELN (LDM) of the UCD pilot station
with respect to the data assigned by the ASHUL
command.
1
2
1
RP
Announcement replay
0 = Once
1 = Repeat within the time specified by the INT parameter
INT
The INT parameter appears when RP = 1.
Enter the replay interval time value in seconds with a range
of 0-30 seconds. (2 seconds increments)
CNT
The number of external trunks to be connected to
an external announcement machine.
DELAY
TIMER
(DLYT)
0-30
TRUNK
NUMBER
(TK)
1-768
ROUTE
NUMBER
(RT)
MESSAGE
TIMER
(MSGT)
0-30
ANNOUNCE-
MENT
OUTPUT
REPLAY
(RP)
0/1
REPLAY
INTERVAL
(INT)
0-30
USER
GROUP
NUMBER
(UGN)
TELEPHONE NUMBER
(TELN)
MAX. 16 DIGITS
RT
Enter the Route Number of
the Announcement Trunk
MSGT
Enter the message timer value in seconds within 0-30
seconds. (2 seconds increments)
However, this value is not effective if the Route data
of Announcement Trunk is assigned as follows:
ARTD, CDN28 ANS=1