ND-70348 (E)
CHAPTER 4
Page 552
Revision 3.0
ASGD
ASGD: Assignment of Special Group Data
1. General
This command is used to assign the station number belonging to the special group which applies to the following
service features:
Off Hook Alarm
Priority Call
Do not Disturb
Room Cut Off
2. Precautions
1.
The call destination of the special group is designated by the ASID command.
2.
The applicable tenant number (TN) range is designated by the ASYD command, SYS 1, INDEX 8.
3.
Since the GN parameter is an intermediate data to the ASID command, enter a unique number for each spe-
cial group.
3. Data Entry Instructions
1 2 5 6 4 5 0
1
STATION NUMBER
(STN)
FUNCTION
NUMBER
(F)
0-7
GROUP
NUMBER
(GN)
1-7
REMARKS
TENANT
NUMBER
(TN)
F
0 = Off Hook Alarm
1 = Do Not Disturb (Only for Hotel System)
2 = Room Cut Off (Only for Hotel System)
3 = Not used
4 = Priority Call 1
5 = Priority Call 2
6 = Priority Call 3
7 = Not used
GN
Enter a unique GN for each
special group
STN
Enter the station number
belongs to the special
group