
ND-70348 (E)
CHAPTER 4
Page 373
Revision 3.0
AICD_T
3. Data Entry Instructions
Note 1:
The existing data can be readout by pressing “Get” button after MG No. and G-ID data is entered.
Note 2:
When the existing Intercom Station is assigned only by Station Number, UGN data is not displayed on the
list. Allocate Telephone Numbers to all the Intercom Stations.
ICMCT
MODULE
GROUP
NUMBER
(MG No.)
00-07
GROUP
ID
NUMBER
(G-ID)
1-50
AUTO/MANUAL
SIGNALING
(A/M)
TENANT
NUMBER
(TN)
CNT
USER
GROUP
NUMBER
(UGN)
BRIDGE
CALL
RESTRICTION
(BCR)
TELEPHONE NUMBER OF INTERCOM
STATION
(ICM TELN)
Max. 16 digits
TELEPHONE NUMBER OF SIGNALLING
STATION
(SIG TELN)
Max. 16 digits
MG No.
Enter the Module Group
number of the Intercom group.
A/M
• Automatic Intercom
• Manual Intercom
CNT
The number of Intercom
Stations.
BCR
• Restricted
• Allowed
G-ID
Enter a unique number for
each Intercom group within a
range from 1 to 50.
SIG TELN
Enter the Telephone Number of the
Intercom member stations which can
receive an Intercom call.
Note 2
ICM TELN
Enter the Telephone Number of the
Intercom member stations which can
originate an Intercom call.
Note 2
1
2