4-56 System Configuration
(1)
Displays the BMC host name or IP address.
(2)
Displays the LCD of the server.
(3)
The power lamp of the server telling you of the power status.
(4)
The same as pressing the POWER switch of the server, but pressing it for 4 or more seconds
(the forced power off) is not supported.
(5)
Performs memory dump on the server (the same as pressing the DUMP switch of the server).
(6)
Makes the Unit ID lamp of the server blink.
(7)
Starts up the remote KVM console.
(8)
Starts up the BMC configuration.
(9)
Stats up the firmware update.
(10)
A user name is displayed here.
(11)
Displays the connectivity with BMC.
(12)
Displays communication security status.
(13)
Displays network access status.
(14)
The status lamp of the server telling you of the server status.
(15)
Opens the window showing system event logs (SEL).
(16)
Opens the window showing the sensor device information (SDR).
(17)
Opens the window showing the information on parts to be replaced for maintenance (FRU).
(18)
Displays the slot position information (module #0 or module #1).
(19)
Displays the slot status (primary or secondary).
(20)
Hides the control panel.
Remote KVM Console
Remote KVM console functions of the BMC allow you to transfer a local console to the browser on
the management PC over a network.
You can make full access to the server from the management PC using video, keyboard and mouse.
CHECK:
The remote KVM console supports the following five resolutions:
1024 x 768
800 x 600
640 x 480
720 x 400
720 x 350
Содержание N8800-096F
Страница 8: ...NEC Express5800 WARNING CAUTION CAUTION...
Страница 9: ......
Страница 15: ......
Страница 22: ...Precautions for Use 1 3 Rack model Front Rear...
Страница 24: ...Precautions for Use 1 5 Water Cooling kit...
Страница 34: ...Precautions for Use 1 15 SAFETY INDICATIONS WARNING 32 5 CAUTION...
Страница 35: ...1 16 Precautions for Use WARNING CAUTION P IW 9 6 7...
Страница 36: ...Precautions for Use 1 17 CAUTION 1...
Страница 37: ...1 18 Precautions for Use WARNING CAUTION...
Страница 38: ...Precautions for Use 1 19 CAUTION CAUTION...
Страница 39: ...1 20 Precautions for Use WARNING CAUTION...
Страница 40: ...Precautions for Use 1 21 CAUTION...
Страница 44: ...Precautions for Use 1 25 SAFETY INDICATIONS WARNING POWER CAUTION...
Страница 45: ...1 26 Precautions for Use WARNING CAUTION AC 4 5m 14 76 ft V 10A 6 7...
Страница 46: ...Precautions for Use 1 27 WARNING CAUTION...
Страница 47: ...1 28 Precautions for Use CAUTION NEC...
Страница 48: ...Precautions for Use 1 29 WARNING CAUTION...
Страница 49: ...1 30 Precautions for Use CAUTION CAUTION...
Страница 50: ...Precautions for Use 1 31 CAUTION EIA...
Страница 51: ...1 32 Precautions for Use 1 9 836 56 3RZHU KXWH3OXV a e a 173 WR e WR 1 SUHVV IW e 1...
Страница 52: ...Precautions for Use 1 33...
Страница 53: ...1 34 Precautions for Use 5 5 WARNING...
Страница 54: ...Precautions for Use 1 35 1 2 3 1 SUHVV IW 4 1 1 SUHVV IW 1 SUHVV KWWS ZZZ QHF FR MS H SUHVV LQGH KWPO...
Страница 55: ...1 36 Precautions for Use...
Страница 68: ...General Description 2 13 Rack model with the front door open...
Страница 73: ...2 18 General Description Rear View Tower model Rack model...
Страница 110: ...Windows Setup and Operation 3 15 7 Configure the mirror of the extended volume...
Страница 128: ...Windows Setup and Operation 3 33 4 The confirmation dialog box appears Click Yes button...
Страница 164: ...System Configuration 4 27 Exit Move the cursor onto Exit to display the Exit menu...
Страница 225: ...4 88 System Configuration This page is intentionally left blank...
Страница 286: ...Installing and Using Utilities 5 61 Sample screen of Server Maintenance Utility...
Страница 327: ...6 14 Maintenance This page is intentionally left blank...
Страница 328: ...Chapter 7 Troubleshooting If the product does not work properly see this chapter before deciding that it is a breakdown...
Страница 381: ...7 54 Troubleshooting This page is intentionally left blank...
Страница 424: ...Specifications A 3...
Страница 425: ......