CHAPTER 14 SERIAL INTERFACE CHANNEL 1
276
User’s Manual U11302EJ4V0UM
Notes 1.
The interval is dependent only on CPU processing.
2.
The data transfer interval includes an error. The data transfer minimum and maximum
intervals are found from the following expressions (n: Value set in ADTI0 to ADTI4).
However, if the minimum calculated by the following expression is smaller than 2/f
SCK
, the
minimum interval time is 2/f
SCK
.
2
7
56
0.5
Minimum = (n + 1)
×
+
+
f
X
f
X
f
SCK
2
7
72
1.5
Maximum = (n + 1)
×
+
+
f
X
f
X
f
SCK
Cautions 1. ADTI should not be written to during operation of the automatic transmit/receive
function.
2. Bits 5 and 6 must be set to 0.
3. When ADTI is used to control the interval time of data transfer by automatic
transmit/receive function, busy control (refer to 14.4.3 (4) (a) Busy control option)
is invalid.
Remarks 1.
f
X
:
Main system clock oscillation frequency
2.
f
SCK
: Serial clock frequency
Содержание mPD780208 Subseries
Страница 2: ...2 User s Manual U11302EJ4V0UM MEMO...