53
CHAPTER 6 CONNECTING PERIPHERAL EQUIPMENT
Table 6-1 outlines the functions of channel 1. For further information on the functions of channel 1, refer to
CHAPTER 8 FUNCTIONS OF RESPECTIVE CHANNELS.
Table 6-1 Functional Outline of Channel 1
Set Item
Functional Outline of Channel 1
Setting
Mode
Modem mode
Fixed
Baud rate
Internal : 300, 600, 1200, 2400, 4800, 9600, 19200, 38400, 78600,
H
153600 [bps] MAX.
External
:
19200 [bps] MAX.
Handshaking
Hardware:
1 character
Fixed
Software :
Flow control
Shared
Character length
8 bits
Fixed
Parity bit
None
Fixed
Stop bit
2 bits
Fixed
Remark H: selected by switch (hardware)
(2) PC bus interface and network interface (channel 3)
Channel 3 is a PC bus interface/network interface port that is used to connect the host machine. As the network
interface, Ethernet is employed.
For details, refer to CHAPTER 5 HOST INTERFACE BOARDS.
Character
specification