![background image](http://html.mh-extra.com/html/nec/express5800-180rb-7/express5800-180rb-7_user-manual_251233114.webp)
4-8
Upgrading Your System
Installing a SCSI SCA Hard Disk Drive in a Hot-Swapping Bay
1.
Remove the front bezel. See “Removing and Installing the Front Bezel” later
in this chapter.
2.
Orient the carrier and drive assembly in front of the hot-swapping bay guide
rails so that metal fingers of the perforated metal bracket attached to the
carrier are facing up. Make sure that the carrier is placed correctly into the
guide rails to avoid damage.
3.
While grasping only the drive carrier handle, firmly push the assembly into
the bay until the drive docks with the hot-swapping backplane connector.
See Figure 4-3
CAUTION
Do not press on the perforated metal bracket of the carrier
when you push the assembly into the bay, or you can
damage the metal fingers of the bracket.
A. Drive carrier latch
Figure 4-3 Installing a Hard Disk Drive
4.
Reinstall the front bezel. See “Removing and Installing the Front Bezel”
later in this chapter.
5.
If you installed a RAID controller board, run the Disk Array Controller
Configuration utility supplied with the board. See the manufacture’s
documentation provided.
Содержание Express5800/180Rb-7
Страница 1: ... U s e r s G u i d e EXPRESS5800 180Rb 7 ...
Страница 2: ...xxx ...
Страница 3: ... U s e r s G u i d e EXPRESS5800 180Rb 7 ...
Страница 10: ...viii Contents ...
Страница 58: ...2 24 Setting Up the System ...
Страница 111: ...Upgrading Your System 4 5 OM10702 A B C D A Fan cover screw B Fan cover C Grasp holes D Fan Figure 4 1 Replacing a Fan ...
Страница 146: ...4 40 Upgrading Your System ...
Страница 166: ...5 20 Problem Solving ...
Страница 186: ...10 Glossary ...
Страница 190: ...4 Equipment Log ...
Страница 195: ...xx ...
Страница 196: ... 456 01564 001 ...