Troubleshooting 8-17
Error
code
Error message
Recommended Action
0B50
Processor #1 with error taken off line.
0B51
Processor #2 with error taken offline.
0B52
Processor #3 with error taken offline.
0B53
Processor #4 with error taken offline.
The CPU is degraded. Contact your
service representative.
0B5F
Forced to use Processor with error
Because an error is detected in every CPU,
the system is forcibly started. Contact your
service representative.
0B60
DIMM group #1 has been disabled
0B61
DIMM group #2 has been disabled
0B62
DIMM group #3 has been disabled
Contact your service representative.
0B70
The error occurred during temperature sensor
reading.
Contact your service representative.
0B71
System Temperature out of the range.
A fan failure or fan clogging may occur.
Contact your service representative to
request the maintenance.
0B74
The error occurred during voltage sensor
reading.
0B75
System voltage out of the range.
0B78
The error occurred during fan sensor reading
Contact your service representative.
0B7C
The error occurred during redundant power
module confirmation
Contact you service representative to
replace the power supply unit.
0B7D
The normal operation can't be guaranteed with
use of only one PSU
Contact you service representative to add an
additional power supply unit or replace the
existing power supply unit.
0B80
BMC Memory Test Failed.
0B81
BMC Firmware Code Area CRC check failed.
0B82
BMC core hardware failure.
0B83
BMC IBF or OBF check failed.
0B8A
BMC SEL area full.
0B8B
BMC progress check timeout.
0B8C
BMC command access failed.
0B8D
Could not redirect the console - BMC Busy -
0B8E
Could not redirect the console - BMC Error -
0B8F
Could not redirect the console - BMC
Parameter Error -
0B90
BMC Platform Information Area corrupted.
0B91
BMC update firmware corrupted.
Turn off the power once and then on again to
start the server. If the error cannot be
corrected, contact your service
representative.
0B92
Internal Use Area of BMC FRU corrupted.
All the commands and functions other than
the FRU command and the EMP function
can be used. This is not a fatal error. Turn
off the power once and then on again to
restart the server. If the error cannot be
corrected, contact your service
representative.
0B93
BMC SDR Repository empty.
Turn off the power once and then on again to
restart the server. If the error cannot be
corrected, contact your service
representative.
Содержание Express5800/140Rc-4
Страница 10: ...iv This page is intentionally left blank ...
Страница 34: ...1 18 Notes on Using Your Server This page is intentionally left blank ...
Страница 93: ...Setting Up Your Server 3 21 21 Install the front bezel Now the installation is completed ...
Страница 110: ...3 38 Setting Up Your Server This page is intentionally left blank ...
Страница 196: ...5 40 Installing the Operating System with Express Setup This page is intentionally left blank ...
Страница 286: ...8 48 Troubleshooting This page is intentionally left blank ...
Страница 360: ...9 74 Upgrading Your Server This page is intentionally left blank ...
Страница 362: ...A 2 Specifications This page is intentionally left blank ...
Страница 400: ...F 4 Product Configuration Record Table This page is intentionally left blank ...