Your Setting
AC-LINK
Stay Off
[Last State]
Power On
Specify the state of power when the AC
power to the server is turn off once and
then on.
Power On
Delay Time
(Sec)
[0] - 255
Specify the power on delay time within the
range between 0 and 255 seconds. The
time specified is valid when "Power On" or
"Last State" is specified for AC LINK.
Platform Event
Filtering
[Disabled]
Enabled
This item becomes meaningless when the
notification feature of remote management
card (RMC) is enabled.
[ ]: Factory-set
IMPORTANT:
To power on the server from the UPS (Uninterruptible
Power Supply), select [Server] - [AC LINK] - [Power On].
The table below shows the operation when the AC power to the server is turn off once and then on
again, depending on the setting of "AC LINK."
Setting of AC LINK
System status before AC power off
Stay Off
Last State
Power On
Operating
Off
On
On
Aborting (DC power being off also)
Off
Off
On
Forced shutdown
Off
Off
On
* Press the power switch continuously for four seconds or longer. This forcibly turns off the
power.
Содержание Express5800/120Rf-1
Страница 32: ...1 16 Notes on Using Your Server This page is intentionally left blank ...
Страница 154: ...4 58 Configuring Your Server This page is intentionally left blank ...
Страница 236: ...6 26 Installing and Using Utilities This page is intentionally left blank ...
Страница 248: ...7 12 Maintenance This page is intentionally left blank ...
Страница 348: ...C 2 IRQ This page is intentionally left blank ...
Страница 408: ...G 4 Product Configuration Record Table This page is intentionally left blank ...