background image

Huawei FusionServer Pro 5885H V5 Server

V100R005

Technical White Paper

Issue

09

Date

2020-06-05

HUAWEI TECHNOLOGIES CO., LTD.

Summary of Contents for FusionServer Pro 5885H V5

Page 1: ...Huawei FusionServer Pro 5885H V5 Server V100R005 Technical White Paper Issue 09 Date 2020 06 05 HUAWEI TECHNOLOGIES CO LTD ...

Page 2: ...cribed in this document may not be within the purchase scope or the usage scope Unless otherwise specified in the contract all statements information and recommendations in this document are provided AS IS without warranties guarantees or representations of any kind either express or implied The information in this document is subject to change without notice Every effort has been made in the prep...

Page 3: ...k which if not avoided will result in death or serious injury Indicates a hazard with a medium level of risk which if not avoided could result in death or serious injury Indicates a hazard with a low level of risk which if not avoided could result in minor or moderate injury Indicates a potentially hazardous situation which if not avoided could result in equipment damage data loss performance dete...

Page 4: ... 07 2019 11 15 This issue is the seventh official release 06 2019 08 23 Added the support for Cascade Lake processors 05 2018 11 30 This issue is the fifth official release 04 2018 07 23 This issue is the fourth official release 03 2018 06 15 This issue is the third official release 02 2018 05 08 This issue is the second official release 01 2018 04 12 This issue is the first official release Huawe...

Page 5: ...er 25 5 4 2 Memory Subsystem Architecture 26 5 4 3 Memory Compatibility 28 5 4 4 Memory Installation Guidelines 30 5 4 5 Memory Installation Positions 30 5 4 6 Memory Protection Technologies 33 5 5 Storage 34 5 5 1 Drive configurations 34 5 5 2 Drive Numbering 34 5 5 3 Drive Indicators 36 5 5 4 RAID Controller Card 37 5 6 I O Expansion 37 5 6 1 PCIe Cards 37 5 6 2 PCIe Slots 38 5 6 3 PCIe Slot Des...

Page 6: ...ions 58 8 1 Safety Instructions 58 8 2 Maintenance and Warranty 61 9 System Management 62 10 Certifications 64 A Appendix 67 A 1 Product SN 67 A 2 Operating Temperature Limitations 68 A 3 RAS Features 69 A 4 Sensor List 71 B Glossary 78 B 1 A E 78 B 2 F J 79 B 3 K O 79 B 4 P T 79 B 5 U Z 80 C Acronyms and Abbreviations 81 C 1 A E 81 C 2 F J 82 C 3 K O 83 C 4 P T 84 C 5 U Z 86 Huawei FusionServer P...

Page 7: ...r various applications such as databases cloud computing virtualization and in memory computing The 5885H V5 is a highly expandable server delivering high performance computing large storage capacity low power consumption and high density It is easy to deploy and manage and supports virtualization Figure 1 1 5885H V5 with 25 drives Huawei FusionServer Pro 5885H V5 Server Technical White Paper 1 Ov...

Page 8: ...processor core to run up to two threads improving parallel computation capability The hardware assisted Intel Virtualization Technology Intel VT allows operating system OS vendors to better use hardware to address virtualization workloads With Intel Advanced Vector Extensions 512 AVX 512 applications can pack 32 double precision and 64 single precision floating point operations per second in a clo...

Page 9: ...against power failures The server provides simplified O M and efficient troubleshooting through the UID HLY indicators on the front panel fault diagnosis LED touch LCD diagnosis panel and iBMC web interface The SSDs offer better reliability than HDDs ensuring continued system performance The built in iBMC monitors system parameters in real time triggers alarms and performs recovery actions to mini...

Page 10: ...onfiguring IPv4 addresses IPv4 address subnet mask and gateway and IPv6 addresses IPv6 address prefix length and gateway for this port Energy Efficiency The 80 Plus Platinum power supply units PSUs of multiple power ratings provide 94 power efficiency at 50 load Efficient voltage regulator down VRD power supplies for boards minimize the energy loss from DC DC power conversion Area based Proportion...

Page 11: ...ckplane 5 Cable organizer 6 Chassis 7 Air duct 8 Fan adapter board 9 Drive backplane 10 Fan modules 11 Drives 12 DVD drive or LCD 13 Memory modules 14 Heat sinks 15 Processors 16 Daughter board Huawei FusionServer Pro 5885H V5 Server Technical White Paper 3 Physical Structure Issue 09 2020 06 05 Copyright Huawei Technologies Co Ltd 5 ...

Page 12: ...17 Supercapacitor 18 Mainboard 19 TPM TCM Huawei FusionServer Pro 5885H V5 Server Technical White Paper 3 Physical Structure Issue 09 2020 06 05 Copyright Huawei Technologies Co Ltd 6 ...

Page 13: ...4Logical Structure Huawei FusionServer Pro 5885H V5 Server Technical White Paper 4 Logical Structure Issue 09 2020 06 05 Copyright Huawei Technologies Co Ltd 7 ...

Page 14: ...memory modules The CPUs processors interconnect with each other through three UPI links at a speed of up to 10 4 GT s The server provides 15 standard PCIe 3 0 slots of various specifications Huawei FusionServer Pro 5885H V5 Server Technical White Paper 4 Logical Structure Issue 09 2020 06 05 Copyright Huawei Technologies Co Ltd 8 ...

Page 15: ...3 0 ports and serial ports RJ45 The server provides four LOM ports including two 10GE optical ports and two GE electrical ports Huawei FusionServer Pro 5885H V5 Server Technical White Paper 4 Logical Structure Issue 09 2020 06 05 Copyright Huawei Technologies Co Ltd 9 ...

Page 16: ...5 6 I O Expansion 5 7 PSUs 5 8 Fans 5 9 LCD 5 10 Boards 5 1 Front Panel 5 1 1 Appearance 8 x 2 5 SAS SATA drive configuration Figure 5 1 Front view Huawei FusionServer Pro 5885H V5 Server Technical White Paper 5 Hardware Description Issue 09 2020 06 05 Copyright Huawei Technologies Co Ltd 10 ...

Page 17: ...x SAS SATA 8 x NVMe driver configuration Figure 5 2 Front view 1 Drives 2 Slide out label plate with an SN label 3 Fan modules 25 x 2 5 SAS SATA drive configuration Figure 5 3 Front view Huawei FusionServer Pro 5885H V5 Server Technical White Paper 5 Hardware Description Issue 09 2020 06 05 Copyright Huawei Technologies Co Ltd 11 ...

Page 18: ...tus indicator 3 LOM port 3 connection status indicator 4 LOM port 4 connection status indicator 5 Non Maskable Interrupt NMI button 6 Fault diagnosis LED 7 Health status indicator 8 UID button indicator 9 Power button indicator 10 Fan status indicator 24 x 2 5 24 SAS SATA or 16 x SAS SATA 8 x NVMe drive configuration Huawei FusionServer Pro 5885H V5 Server Technical White Paper 5 Hardware Descript...

Page 19: ...s LED 6 Health status indicator 7 UID button indicator 8 Power button indicator 9 NMI button 10 Fan status indicator 25 x 2 5 SAS SATA drive configuration Figure 5 6 Indicators and buttons on the front panel 1 LOM port 1 connection status indicator 2 LOM port 2 connection status indicator Huawei FusionServer Pro 5885H V5 Server Technical White Paper 5 Hardware Description Issue 09 2020 06 05 Copyr...

Page 20: ...ng Power button indicator Power indicator Off The device is not powered on Steady green The device is powered on Blinking yellow The power button is locked The power button is locked when the iBMC is starting Steady yellow The device is ready to power on Power button When the device is powered on you can press this button to gracefully shut down the OS When the device is powered on holding down th...

Page 21: ...linking red at 1 Hz A major alarm has been generated on the system Blinking red at 5 Hz A critical alarm has been generated on the system Steady green The device is operating properly NMI button A non maskable interrupt NMI is generally triggered to stop the OS for debugging To trigger an NMI press this button or click the button on the iBMC WebUI NOTICE Press the NMI button only when the OS is ab...

Page 22: ...ice system is powered off As long as the LOM ports are properly connected to other working network devices the network ports will remain connected and the indicators are on Fan status indicator Off The fan module is powered off Blinking red An alarm has been generated on the fan module Steady green The fan module is working properly 5 1 3 Ports Port Positions 8 x 2 5 SAS SATA drive configuration F...

Page 23: ... on the front panel 1 USB 2 0 ports 2 VGA port 3 USB 3 0 port 25 x 2 5 SAS SATA drive configuration Figure 5 9 Ports on the front panel 1 USB 2 0 ports Huawei FusionServer Pro 5885H V5 Server Technical White Paper 5 Hardware Description Issue 09 2020 06 05 Copyright Huawei Technologies Co Ltd 17 ...

Page 24: ...y The server may operate abnormally if an abnormal USB device is connected USB 3 0 1 Note The number of ports varies depending on server configuration This table lists the maximum number of ports in different configurations 5 2 Rear Panel 5 2 1 Appearance Figure 5 10 Rear view 1 PCIe slot 1 2 PCIe slot 2 3 PCIe slot 3 4 PCIe slot 4 5 PCIe slot 5 6 PCIe slot 6 Huawei FusionServer Pro 5885H V5 Serve...

Page 25: ...ns Figure 5 11 Indicators on the rear panel 1 Health status indicator 2 UID indicator 3 Connection status indicator Data transmission status indicator for GE electrical port 1 4 Connection status indicator Data transmission status indicator for GE electrical port 2 Huawei FusionServer Pro 5885H V5 Server Technical White Paper 5 Hardware Description Issue 09 2020 06 05 Copyright Huawei Technologies...

Page 26: ...plied Blinking green at 1 Hz The input is normal the server is in standby state and the PSU is in MV6 mode output voltage is 6 7 V The input is overvoltage or undervoltage The PSU is in deep hibernation mode Blinking green at 4 Hz The firmware is being upgraded online Steady green The power input and output are normal Steady orange The input is normal but no power output is supplied NOTE The possi...

Page 27: ... Data is being transmitted Connection status indicator for the management network port Off The network port is not connected Steady green The network port is properly connected Connection status indicator Data transmission status indicator for 10GE electrical port Off The network port is not connected Blinking green Data is being transmitted Steady green The network port is properly connected Conn...

Page 28: ...VGA port 9 PSU sockets Port Description Table 5 4 Ports on the rear panel Port Type Quantity Description 10GE optical port 10GE SFP 2 10GE LOM service ports optical GE electrical port 1000BASE T 2 GE LOM service ports electrical VGA port DB15 1 Used to connect a display terminal such as a monitor or KVM Huawei FusionServer Pro 5885H V5 Server Technical White Paper 5 Hardware Description Issue 09 2...

Page 29: ... a USB device NOTICE Before connecting an external USB device check that the USB device functions properly The server may operate abnormally if an abnormal USB device is connected PSU sockets 4 Used to connect to the power distribution unit PDU in the cabinet You can select the number of power supply units PSUs as required NOTE When determining the quantity of PSUs ensure that the rated power of t...

Page 30: ...ting a LOM port to a PoE device may cause link communication failure or even damage the NIC The electrical LOM ports do not support SR IOV Forcibly powering off a server will cause intermittent NC SI disconnection and disable the Wake on LAN WOL function of the LOM ports To restore the NC SI connection refresh the iBMC WebUI 5 3 Processor The server supports two or four processors If two processor...

Page 31: ...ou can determine the memory module properties based on the label attached to the memory module Figure 5 14 Memory identifier Huawei FusionServer Pro 5885H V5 Server Technical White Paper 5 Hardware Description Issue 09 2020 06 05 Copyright Huawei Technologies Co Ltd 25 ...

Page 32: ...P 15 T 17 7 DIMM type R RDIMM L LRDIMM 5 4 2 Memory Subsystem Architecture The 5885H V5 provides 48 memory slots Each processor integrates six memory channels Install DIMMs in primary memory channels first If the primary memory channel is not populated the DIMMs in secondary memory channels cannot be used Table 5 6 Memory channels CPU Memory Channel Memory Slot CPU 1 A primary DIMM000 A A DIMM001 ...

Page 33: ...imary DIMM120 C C DIMM121 I D primary DIMM130 D D DIMM131 J E primary DIMM140 E E DIMM141 K F primary DIMM150 F F DIMM151 L CPU 3 A primary DIMM200 A A DIMM201 G B primary DIMM210 B B DIMM211 H C primary DIMM220 C C DIMM221 I D primary DIMM230 D D DIMM231 J E primary DIMM240 E E DIMM241 K Huawei FusionServer Pro 5885H V5 Server Technical White Paper 5 Hardware Description Issue 09 2020 06 05 Copyr...

Page 34: ...ed supported by a processor Maximum operating speed of a DIMM The DDR4 DIMMs of different types RDIMM and LRDIMM and specifications capacity bit width rank and height cannot be used together Contact your local Huawei sales representative or use the Intelligent Computing Compatibility Checker to determine the components to be used The memory can be used with Intel Xeon Scalable Skylake and Cascade ...

Page 35: ...ported by each channel varies depending on the number of ranks supported by each channel Number of DIMMs supported by each channel Number of ranks supported by each memory channel Number of ranks supported by each DIMM A memory channel supports more than eight ranks for LRDIMMs A quad rank LRDIMM generates the same electrical load as a single rank RDIMM on a memory bus Table 5 7 DDR4 memory specif...

Page 36: ...ng mode Memory sparing mode Comply with the general installation guidelines Each memory channel must have a valid online spare configuration The channels can have different online spare configurations Each populated channel must have a spare rank Memory mirroring mode Comply with the general installation guidelines Each processor supports two integrated memory controllers IMCs At least two channel...

Page 37: ...ed on the mainboard and CPUs 3 and 4 are located on the daughter board Memory slots on the mainboard Figure 5 15 Memory slots mainboard Memory slots on the daughter board Huawei FusionServer Pro 5885H V5 Server Technical White Paper 5 Hardware Description Issue 09 2020 06 05 Copyright Huawei Technologies Co Ltd 31 ...

Page 38: ...ts daughter board Figure 5 17 DDR4 memory installation guidelines 2 processors Huawei FusionServer Pro 5885H V5 Server Technical White Paper 5 Hardware Description Issue 09 2020 06 05 Copyright Huawei Technologies Co Ltd 32 ...

Page 39: ...oring Address range mirroring SDDC SDDC 1 Rank sparing mode Static virtual lockstep Faulty DIMM isolation Memory thermal throttling Memory address parity protection Memory demand patrol scrubbing Device tagging Data scrambling Huawei FusionServer Pro 5885H V5 Server Technical White Paper 5 Hardware Description Issue 09 2020 06 05 Copyright Huawei Technologies Co Ltd 33 ...

Page 40: ... 20 to 23 support only NVMe drives Slots 4 to 19 support only SAS SATA drives 1 x RAID controller card 2 x NVMe adapter 25 x 2 5 SAS SATA drive configuration 25 Slots 0 to 24 support only SAS SATA drives 1 x RAID controller card a A RAID controller card is required only when SAS or SATA drives are installed in front slots 0 to 3 Contact your local Huawei sales representative or use the Intelligent...

Page 41: ...8 x NVMe drive configuration Figure 5 20 Drive numbering 25 x 2 5 SAS SATA drive configuration Figure 5 21 Drive numbering Huawei FusionServer Pro 5885H V5 Server Technical White Paper 5 Hardware Description Issue 09 2020 06 05 Copyright Huawei Technologies Co Ltd 35 ...

Page 42: ...normally or data on the primary drive is being rebuilt Steady on Blinking at 1 Hz The drive is being located Blinking at 1 Hz Blinking at 1 Hz The data on the secondary drive is being rebuilt Off Steady on A member drive in the RAID array is removed Steady on Steady on The drive is faulty NVMe Drive Indicators Figure 5 23 NVMe drive indicators Huawei FusionServer Pro 5885H V5 Server Technical Whit...

Page 43: ...D Controller Card The RAID controller card supports RAID configuration RAID level migration and drive roaming Contact your local Huawei sales representative or use the Intelligent Computing Compatibility Checker to determine the components to be used For details about the RAID controller card see Huawei V5 Server RAID Controller Card User Guide 5 6 I O Expansion 5 6 1 PCIe Cards PCIe cards provide...

Page 44: ...F Slot Size LOM CPU 1 PCIe 3 0 x4 Port2D 0x24 0x 03 0x00 Slot 1 CPU 3 PCIe 3 0 x8 x4 Port1A 0x83 0x 00 0x00 FHFL Slot 2 CPU 3 PCIe 3 0 x16 x16 Port3A 0xB1 0x 00 0x00 FHFL Slot 3 CPU 3 PCIe 3 0 x8 x4 Port1B 0x83 0x 00 0x08 FHFL Slot 4 CPU 1 PCIe 3 0 x16 X16 Port3A 0x32 0x 00 0x00 FHFL Slot 5 CPU 3 PCIe 3 0 x8 x8 Port1C 0x83 0x 00 0x10 FHHL Slot 6 CPU 4 PCIe 3 0 x8 x8 Port2A 0xE2 0x 00 0x00 FHHL Hua...

Page 45: ...er is fully configured with PCIe devices The values may vary if the server is not fully configured with PCIe devices or if a PCIe card with a PCI bridge is configured The PCIe x16 slots are backward compatible with PCIe x8 PCIe x4 and PCIe x1 cards The PCIe cards are not forward compatible That is the PCIe slot width cannot be smaller than the PCIe card link width The full height half length FHHL ...

Page 46: ...ty Checker to determine the components to be used For a server configured with one or two 1500 W Platinum AC PSUs When the input voltage is from 100 V AC to 132 V AC the output power drops to 1000 W Two 1500 W AC Platinum PSUs can serve as 1700 W PSUs Figure 5 25 PSU positions 5 8 Fans The server supports five fan modules The fan modules are hot swappable The server tolerates failure of a single f...

Page 47: ...tus of server components and enables users to set the IP address of the iBMC management network port on the server The LCD and the server iBMC form an LCD subsystem The LCD directly obtains device information from the iBMC The LCD subsystem does not store device data but allows users to query device status and alarms Huawei FusionServer Pro 5885H V5 Server Technical White Paper 5 Hardware Descript...

Page 48: ...ent power of the server CPU temperature and inlet temperature Info Displays the IP address and MAC address of the iBMC management network port MAC addresses of host LOM ports device SNs asset information and firmware version Setting Sets the IP address of the iBMC management network port Huawei FusionServer Pro 5885H V5 Server Technical White Paper 5 Hardware Description Issue 09 2020 06 05 Copyri...

Page 49: ...rds 5 10 1 Mainboard Figure 5 30 5885H V5 mainboard 1 PCIe card slots 7 to 15 from right to left 2 PCIe riser slots J207 for CPU 1 and J230 for CPU 4 Huawei FusionServer Pro 5885H V5 Server Technical White Paper 5 Hardware Description Issue 09 2020 06 05 Copyright Huawei Technologies Co Ltd 43 ...

Page 50: ...r connector BP PWR J237 24 Left mounting ear connector LEFT EAR CONN BOARD J115 25 PSU backplane power connectors J225 J226 J239 26 PSU backplane signal connectors J238 27 VROC key port J144 e a The upper one is an RJ45 serial port and the lower one is an RJ45 management port b The BMC_SER_MANUAL pin is used for changing the connection direction of the physical serial port The CLEAR_BMC_PW pin is ...

Page 51: ...ard and CPUs 3 and 4 are on the daughter board The mainboard and daughter board are interconnected through high speed backplane connectors Figure 5 31 Daughter board 1 Slimline connectors for connecting the daughter board and the riser card Huawei FusionServer Pro 5885H V5 Server Technical White Paper 5 Hardware Description Issue 09 2020 06 05 Copyright Huawei Technologies Co Ltd 45 ...

Page 52: ...lane 8 x 2 5 SAS SATA drive backplane Figure 5 33 8 x 2 5 SAS SATA drive backplane 1 Signal cable connector J1 2 DVD drive power connector J11 Huawei FusionServer Pro 5885H V5 Server Technical White Paper 5 Hardware Description Issue 09 2020 06 05 Copyright Huawei Technologies Co Ltd 46 ...

Page 53: ...r PORT 2A J30 5 SAS cable connector PORT 1B J29 6 SAS cable connector PORT 1A J28 7 Backplane power connector J24 8 Backplane signal cable connector J1 24 x 2 5 16 x SAS SATA 8 x NVMe drive backplane Figure 5 35 24 x 2 5 16 x SAS SATA 8 x NVMe drive backplane 1 NVMe PORT B_N2 J26 2 NVMe PORT B_N0 J24 3 NVMe PORT B_N1 J25 4 SAS cable connector PORT C_0 J28 Huawei FusionServer Pro 5885H V5 Server Te...

Page 54: ...B_N3 J27 25 x 2 5 SAS SATA drive backplane Figure 5 36 25 x 2 5 SAS SATA drive backplane 1 SAS cable connector PORT A J28 2 SAS cable connector PORT B J29 3 SAS cable connector REAR PORT J31 4 Backplane signal cable connector J1 5 Backplane power connector J24 Huawei FusionServer Pro 5885H V5 Server Technical White Paper 5 Hardware Description Issue 09 2020 06 05 Copyright Huawei Technologies Co L...

Page 55: ...controller and six memory channels Built in PCIe controller supporting PCIe 3 0 and 48 lanes per processor Three UPI buses between processors providing up to 10 4GT s transmission per channel Up to 28 cores 2 7 GHz Max 3 8 GHz four cores Min 1 375 MB L3 cache per core Max 205 W TDP NOTE The preceding information is for reference only Use the Intelligent Computing Compatibility Checker to obtain sp...

Page 56: ...ifferent types RDIMM and LRDIMM and specifications capacity bit width rank and height cannot be used together NOTE The preceding information is for reference only Use the Intelligent Computing Compatibility Checker to obtain specific information Huawei FusionServer Pro 5885H V5 Server Technical White Paper 6 Product Specifications Issue 09 2020 06 05 Copyright Huawei Technologies Co Ltd 50 ...

Page 57: ...696 Configure syslog For details see https kb vmware com s article 2003322 The M 2 SSD cannot be used to store data due to poor endurance In write intensive applications the M 2 SSD will wear out in a short time Use enterprise level high endurance HE SSDs or HDDs for data storage The M 2 SSD is not recommended for write intensive service software due to poor endurance Do not use the M 2 SSD as the...

Page 58: ...e link communication failure or even damage the NIC I O expansion 15 PCIe 3 0 slots Six slots for riser cards and nine onboard slots For details see PCIe Slots and PCIe Slot Description Support Huawei proprietary PCIe SSD cards to bolster I O performance for applications such as searching caching and download services NOTE The preceding information is for reference only Use the Intelligent Computi...

Page 59: ...USB flash drive Video card An SM750 video chip with 32 MB display memory is integrated on the mainboard The maximum display resolution is 1920 x 1200 at 60 Hz with 16 M colors NOTE The integrated video card can provide the maximum display resolution 1920 x 1200 only after the video card driver matching the operating system version is installed Otherwise only the default resolution supported by the...

Page 60: ... storage temperature 72 hours 21 C to 27 C 69 8 F to 80 6 F Maximum temperature change rate 20 C h 36 F h NOTE The highest operating temperature varies depending on the server configuration For details see Operating Temperature Limitations Relative humidity RH non condensing Operating humidity 8 to 90 Storage humidity 72 hours 5 to 95 Long term storage humidity 72 hours 30 to 69 Maximum change rat...

Page 61: ...rements of the ANSI ISA 71 04 2013 standard on gaseous corrosion Silver corrosion rate test 200 Å month Particle contaminant The equipment room environment meets the requirements of ISO 14664 1 Class 8 There is no explosive conductive magnetic or corrosive dust in the equipment room NOTE It is recommended that the particulate pollution in the equipment room be monitored by a professional agency Ac...

Page 62: ... between the front and rear mounting bars Ball bearing rail kit applies to cabinets with a distance of 610 mm to 914 mm 24 02 in to 35 98 in between the front and rear mounting bars Weight in full configuration Maximum net weight Server with 8 x 2 5 drives 42 kg 92 61 lb Server with 24 x 2 5 drives 44 kg 97 02 lb Server with 25 x 2 5 drives 45 kg 99 23 lb Packing materials 9 kg 19 85 lb Power cons...

Page 63: ...re supported NOTICE Do not use incompatible components Otherwise the server may fail to work properly The technical support and warranty do not cover faults caused by incompatible components Huawei FusionServer Pro 5885H V5 Server Technical White Paper 7 Software and Hardware Compatibility Issue 09 2020 06 05 Copyright Huawei Technologies Co Ltd 57 ...

Page 64: ... a forklift Take protective measures if a Class A product is used in residential areas as it is likely to cause radio interference Personal Safety Only personnel certified or authorized by Huawei are allowed to install the hardware Stop any operation that may cause personal injury or equipment damage report the problem to a project supervisor immediately and take protective measures Do not operate...

Page 65: ...ure 8 2 Conductive objects to be removed Figure 8 3 shows how to wear an ESD wrist strap a Secure the ESD wrist strap around your wrist b Fasten the strap buckle and ensure that the ESD wrist strap is in contact with your skin c Insert the ground terminal attached to the ESD wrist strap into the jack on the grounded rack or chassis Huawei FusionServer Pro 5885H V5 Server Technical White Paper 8 Sa...

Page 66: ...e handles of the installed modules such as the PSUs fan modules drives and the mainboard Handle the equipment with care Exercise caution when using tools that could cause personal injury If the device is configured with active and standby PSUs connect power cables of active and standby PSUs to different power distribution units PDUs to ensure reliable system operating Properly ground a device befo...

Page 67: ... number of organizations Table 8 1 Maximum weight one person is permitted to carry Organization Weight kg lb European Committee for Standardization CEN 25 55 13 International Organization for Standardization ISO 25 55 13 National Institute for Occupational Safety and Health NIOSH 23 50 72 Health and Safety Executive HSE 25 55 13 General Administration of Quality Supervision Inspection and Quaranti...

Page 68: ...nd text console redirection Remote virtual media IPMI SNMP Common information model CIM Redfish Browser based login Specifications Table 9 1 iBMC specifications Feature Description Management interface Integrates with any standard management system through the following interfaces or protocols IPMI CLI HTTPS SNMP Redfish Fault detection Detects and accurately locates faults in hardware for example...

Page 69: ...erations Fault reproduction Reproduces faults to help diagnose them quickly Screen snapshots and screen videos Allows users to view screenshots and videos without login facilitating routine preventive maintenance inspection PMI Black Box Allows users to enable or disable the black box function and download black box data DNS LDAP Supports domain management and directory services significantly simp...

Page 70: ...China RoHS SJ T 11363 2006 SJ T 11364 2006 GB T 26572 2011 China CCC GB4943 1 2011 GB9254 2008 Class A GB17625 1 2012 Huawei FusionServer Pro 5885H V5 Server Technical White Paper 10 Certifications Issue 09 2020 06 05 Copyright Huawei Technologies Co Ltd 64 ...

Page 71: ...EC 61000 6 4 2006 A1 2010 EN 61000 6 4 2007 A1 2011 RoHS 2002 95 EC 2011 65 EU EN 50581 2012 REACH EC NO 1907 2006 WEEE 2002 96 EC 2012 19 EU America FCC FCC CFR47 Part 15 2005 Class A Canada IC ICES 003 2004 Class A Australia C tick AS NZS CISPR 22 2009 Japan VCCI VCCI V 3 2012 Saudi SASO IEC 60950 1 2005 2nd Edition A1 2009 EN 60950 1 2006 A11 2009 A1 2010 A12 2011 Nigeria SONCAP IEC 60950 1 200...

Page 72: ...ards Kuwait Kucas IEC 60950 1 2005 2nd Edition A1 2009 EN 60950 1 2006 A11 2009 A1 2010 A12 2011 Huawei FusionServer Pro 5885H V5 Server Technical White Paper 10 Certifications Issue 09 2020 06 05 Copyright Huawei Technologies Co Ltd 66 ...

Page 73: ...le Table A 1 SN description Callout No Description 1 SN ID two characters which is 21 2 Material identification code 8 characters that is the processing code 3 Vendor code two characters 10 indicates Huawei and other values indicate outsourcing vendors Huawei FusionServer Pro 5885H V5 Server Technical White Paper A Appendix Issue 09 2020 06 05 Copyright Huawei Technologies Co Ltd 67 ...

Page 74: ...espectively 5 Sequence number six characters 6 RoHS compliance one character Y indicates RoHS compliant 7 Internal model that is product name A 2 Operating Temperature Limitations Table A 2 Operating temperature limitations Configuratio n Max 35 C 95 F Max 40 C 104 F Max 45 C 113 F 8 x 2 5 SAS SATA drive configuration All options supported Options supported processors of up to 205 W Options not su...

Page 75: ...variety of Reliability Availability and Serviceability RAS features You can configure these features for better RAS For details about how to configure RAS features see Huawei Server Purley Platform BIOS Parameter Reference Table A 3 RAS features Module Feature Description CPU Corrected Machine Check Interrupt Corrects error triggered interruption DIMM Failed DIMM Isolation Identifies a faulty DIMM...

Page 76: ... errors PCIe PCIe Advanced Error Reporting Improves server serviceability UPI Intel UPI Link Level Retry Provides a retry mechanism upon errors to improve UPI reliability Intel UPI Protocol Protection via CRC Provides cyclic redundancy check CRC protection for UPI packets to improve system reliability System Core Disable for Fault Resilient Boot FRB Isolates a faulty CPU core during startup to imp...

Page 77: ...latform Environment Control Interface PECI If a fatal error occurs in the system the out of band system collects onsite data to facilitate fault analysis and locating and improve system serviceability BIOS Abstraction Layer for Error Handling The BIOS processes errors and reports the error information to the OS and the server in compliance with specifications to improve system serviceability BIOS ...

Page 78: ...47 on the mainboard CPU 3 Components in positions U4351 and U4408 on the mainboard CPU 4 Components in positions U4411 and U4414 on the mainboard N indicates the CPU number The value ranges from 1 to 4 CPUN VRD Temp CPU VRD temperature CPU 1 Component in position U4316 on the mainboard CPU 2 Component in position U4430 on the mainboard CPU 3 Component in position U4370 on the mainboard CPU 4 Compo...

Page 79: ...atus DIMMs of CPUN N indicates the DIMM number The value ranges from 1 to 4 PSN Fan Status PSU fan status PSU N indicates the PSU number The value ranges from 1 to 4 PSN Temp Status PSU presence PSN Status PSU status Power Button Power button Right mounting ear UID Button UID button status DISKN Drive status Drive N indicates the physical drive slot number FANN F Presence Fan presence Fan module N...

Page 80: ...ACPI State ACPI status SysFWProgress Software processes and system startup errors SysRestart System restart causes Boot Error Boot error Watchdog2 Watchdog Mngmnt Health Management subsystem health status Riser1 Card Entity presence SAS Cable Entity presence PCIe RAIDN Temp LSI SAS3508 RAID controller card temperature PCIe RAIDN Temp Avago SAS3004 RAID controller card temperature M2 Temp PCIeN Max...

Page 81: ...us SEL full or clearing events Op Log Full Operation log full or clearing events Sec Log Full Security log full or clearing events CPU Usage CPU usage Memory Usage Memory usage PCIeN Card BBU BBU fault or low voltage on a plug in PCIe RAID controller card BMC Time Hopping Time hopping NTP Sync Failed NTP synchronization failure and recovery events Host Loss System monitoring software BMA link loss...

Page 82: ...utput 12 V voltage detection for soft start CPU4 fan module SYS 12V_4 Mainboard 12 0 V voltage the fourth output 12 V output voltage detection for soft start drive backplane module SYS 12V_5 Mainboard 12 0 V voltage the fourth output 12 V output voltage detection for soft start drive backplane module Standby 5V Mainboard standby 5 0 V voltage Standby 3 3V Mainboard standby 3 3 V voltage Standby 1 ...

Page 83: ...oltage CPUN DDR VDDQ2 CPUN VSA CPU VSA voltage CPUN VCCIO CPU VCCIO voltage PCH VPVNN PCH PVNN voltage PCH PRIM 1V05 PCH 1 05 V voltage SSDN Temp ES3000 V3 temperature Huawei FusionServer Pro 5885H V5 Server Technical White Paper A Appendix Issue 09 2020 06 05 Copyright Huawei Technologies Co Ltd 77 ...

Page 84: ...e the objects E ejector lever A part on the panel of a device used to facilitate installation or removal of the device Ethernet A baseband local area network LAN architecture developed by Xerox Corporation by partnering with Intel and DEC Ethernet uses the Carrier Sense Multiple Access Collision Detection CSMA CD access method and allows data transfer over various cables at 10 Mbit s The Ethernet ...

Page 85: ...rver It seals the front and rear of the chassis to ensure optimal ventilation and electromagnetic compatibility EMC Peripheral Component Interconnect Express PCIe A computer bus PCI which uses the existing PCI programming concepts and communication standards but builds a faster serial communication system Intel is the main sponsor for PCIe PCIe is used only for internal interconnection A PCI syste...

Page 86: ...ecial computer that provides services for clients over a network system event log SEL A non volatile area and interfaces used to store system events for later fault diagnosis and system recovery B 5 U Z U U A unit defined in International Electrotechnical Commission IEC 60297 1 to measure the height of a cabinet or chassis 1 U 44 45 mm UltraPath Interconnect UPI A point to point processor intercon...

Page 87: ...Vector Extensions B BBU backup battery unit BIOS Basic Input Output System BMC baseboard management controller C CD calendar day CE Conformite Europeenne CIM Common Information Model CLI command line interface Huawei FusionServer Pro 5885H V5 Server Technical White Paper C Acronyms and Abbreviations Issue 09 2020 06 05 Copyright Huawei Technologies Co Ltd 81 ...

Page 88: ...an Computer Manufacturer Association EDB Execute Disable Bit EN European Efficiency ERP enterprise resource planning ETS European Telecommunication Standards C 2 F J F FB DIMM Fully Buffered DIMM FC Fiber Channel FCC Federal Communications Commission FCoE Fibre Channel over Ethernet FTP File Transfer Protocol G GE Gigabit Ethernet Huawei FusionServer Pro 5885H V5 Server Technical White Paper C Acr...

Page 89: ...ternet Data Center IEC International Electrotechnical Commission IEEE Institute of Electrical and Electronics Engineers IGMP Internet Group Message Protocol IOPS input output operations per second IP Internet Protocol IPC intelligent power capability IPMB Intelligent Platform Management Bus IPMI Intelligent Platform Management Interface C 3 K O K KVM keyboard video and mouse Huawei FusionServer Pr...

Page 90: ... Controller Sideband Interface C 4 P T P PCIe Peripheral Component Interconnect Express PDU power distribution unit PHY physical layer PMBUS power management bus POK power OK PWM pulse width modulation PXE Preboot Execution Environment Q QPI Quick Path Interconnect Huawei FusionServer Pro 5885H V5 Server Technical White Paper C Acronyms and Abbreviations Issue 09 2020 06 05 Copyright Huawei Techno...

Page 91: ... single device data correction SERDES serializer deserializer SGMII serial gigabit media independent interface SMI serial management interface SMTP Simple Mail Transfer Protocol SNMP Simple Network Management Protocol SOL serial over LAN SONCAP Standards Organization of Nigeria Conformity Assessment Program SSD solid state drive SSE Streaming SIMD Extensions T TACH tachometer signal TBT Turbo Boos...

Page 92: ... Interface UID unit identification light UL Underwriter Laboratories Inc USB Universal Serial Bus V VCCI Voluntary Control Council for Interference by Information Technology Equipment VGA Video Graphics Array VLAN virtual local area network VRD voltage regulator down W WEEE waste electrical and electronic equipment WSMAN Web Service Management Huawei FusionServer Pro 5885H V5 Server Technical Whit...

Reviews: