Appendix A
Specifications
NEC Express5800/320Lb
NEC Express5800/320Lb-R
Item
N8800-048E N8800-049E
CPU Type
Intel
®
Xeon™ Processor
×
1
Clock/second
cache
2.4GHz/512KB
Number of processors
1
Chipset
Server Works Server Set III GC-LE
512MB (256MB
×
2*)
Standard
*Each module has two DIMMs in standard configuration.
Maximum
3GB (The standard DIMM must be replaced.)
Expansion unit
2 DIMMs (256MB
×
2/ 512 MB
×
2)
Memory module
DDR200 SDRAM DIMM (Registered Type)
Memory
Error check
ECC
Graphics (VRAM)
CT69000 (VRAM 2MB)
Floppy disk (standard) 3.5-inch drive
×
1 (USB)
Hard disk (standard)
None
Hard disk (maximum)
879.0GB* (146.5GB
×
6)
* The user area is reduced to a half of the physical capacity
due to software mirroring.
Auxiliary
input
device
CD-ROM (standard)
ATAPI interface
×
2 (Load on tray type, x24 speed)
5.25 inch
None
File bay
3.5 inch
6 slots
PCI
6 slots
Additional
slot
(2 slots are used for graphics board.)
LAN interface
1000BASE-T/100BASE-TX/10BASE-T (2 ports);
100BASE-TX/10BASE-T (2 ports)
USB
4-pin (2 ports) 2 ports are used by keyboard and external USB
FDD.
Serial
D-sub 9-pin (2 ports)
SCSI
VHDCI 68-pin connector (2 ports)
Network
RJ-45 (4 ports)
External
interface
Display
MINI D-sub 15-pin (1 port)
Cabinet design
Deskside and mini-tower
Rack-mount type
External dimensions
222 (width)*
×
560 (height)
×
795 (depth) mm
*370mm if stabilizers included
480 (width)
×
177 (height)
×
790 (depth) mm
Weight
68 kg (Max. 73kg)
56 kg (Max. 61kg)
Power supply
100 to 120 VAC
±
10%, 200 to 240 VAC
±
10%, 50/60 Hz
±
1
Hz
Power consumption
880 VA, 870 W
In operation
Temperature 10 to 35°C
Humidity 20 to 80% RH (non-condensing)
Environmental
requirements
In storage
Temperature -10 to 55°C
Humidity 20 to 80% RH (non-condensing)
Содержание Express 5800/320Lb-R
Страница 1: ...N8800 048E 049E NEC Express5800 320Lb 320Lb R User s Guide 1st Edition 10 2004 856 124161 901 A ...
Страница 10: ...iv This page is intentionally left blank ...
Страница 14: ...viii Setup of Optional PCI Board 8 43 Appendix A Specifications A 1 Appendix B I O Port Address B 1 ...
Страница 17: ...1 3 Label D Label C Label B Label A Label E ...
Страница 18: ...1 4 Rack mount Model Label A Label D Label E Label C Label B ...
Страница 19: ...1 5 Label D Label C Label B Label A Label E ...
Страница 20: ...1 6 PCI CPU Modules PCI Module CPU Module Label A Label B Label A External View Internal View External View ...
Страница 21: ...1 7 Label A Internal View Label B Label B ...
Страница 36: ...1 22 This page is intentionally left blank ...
Страница 44: ...2 8 Front View inside Tower model Rack mount model ...
Страница 83: ...3 9 This page is intentionally left blank ...
Страница 84: ......
Страница 156: ...5 28 PCI Device Detailed information Allows the detailed information of a device on the PCI slot to be viewed ...
Страница 168: ...5 40 Sample screen of NEC ESMPRO Manager 2 Maintenance screen of CPU module CPU Module Maintenance ...
Страница 177: ...5 49 Not support ...
Страница 191: ...5 63 This page is intentionally left blank ...
Страница 192: ......
Страница 205: ...Chapter 7 Troubleshooting If the product does not work properly see this chapter before deciding that it is a breakdown ...
Страница 254: ...8 12 Check the disk status to confirm that the disk is added successfully ...
Страница 273: ...8 31 Chapter 7 Troubleshooting ...
Страница 283: ...8 41 18 Use cable ties to fasten the extra length of cables Cable ties included with cabinet ...
Страница 297: ...8 55 This page is intentionally left blank ...
Страница 298: ......
Страница 300: ...A 2 This page is intentionally left blank ...