7-17
On-screen error message
Cause
Action
0B71 System temperature out
of Range
•
Ambient temperature is
out of range.
•
Fan is faulty.
•
CPU/PCI module board is
faulty.
•
Check the setting in
SETUP
•
Clean the fan.
•
Replace the fan.
•
Replace the CPU/PCI
module board.
0B80 BMC Memory Test Failed
0B81 BMC Firmware Code
Area CRC check failed
0B82 BMC core Hardware
failure
0B83 BMC IBF or OBF check
failed
BMC is faulty.
Replace the PCI module
board.
0B90 BMC Platform
Information Area
corrupted
0B91 BMC update firmware
corrupted
BMC is faulty.
Replace the PCI module
board.
0B92 Internal Use Area of
BMC FRU corrupted
•
SROM is faulty.
•
BMC is faulty.
•
Replace the back panel
board.
•
Replace the PCI module
board.
0B93 BMC SDR Repository
empty
0B94 IPMB signal lines do not
respond
0B95 BMC FRU device failure
0B96 BMC SDR Repository
failure
0B97 BMC SEL device failure
BMC is faulty.
Replace the PCI module
board.
0B98 BMC SEL Overflow
SEL (System Event Log)
overflowed.
Erase the unnecessary SEL.
0BB0 SMBIOS - SROM data
read error
0BB1 SMBIOS - SROM data
checksum bad
•
SROM is faulty.
•
Front panel board is faulty.
Replace the back panel board.
0BD0 1st SMBus device
address not
acknowledged
0BD1 1st SMBus device Error
detected
0BD2 1st SMBus timeout
PCI module board #1 is faulty.
0BD3 2nd SMBus device
address not
acknowledged
0BD4 2nd SMBus device Error
detected
0BD5 2nd SMBus timeout
CPU module board #1 is faulty.
•
Check cable connection.
•
Replace the board.
Содержание Express 5800/320Lb-R
Страница 1: ...N8800 048E 049E NEC Express5800 320Lb 320Lb R User s Guide 1st Edition 10 2004 856 124161 901 A ...
Страница 10: ...iv This page is intentionally left blank ...
Страница 14: ...viii Setup of Optional PCI Board 8 43 Appendix A Specifications A 1 Appendix B I O Port Address B 1 ...
Страница 17: ...1 3 Label D Label C Label B Label A Label E ...
Страница 18: ...1 4 Rack mount Model Label A Label D Label E Label C Label B ...
Страница 19: ...1 5 Label D Label C Label B Label A Label E ...
Страница 20: ...1 6 PCI CPU Modules PCI Module CPU Module Label A Label B Label A External View Internal View External View ...
Страница 21: ...1 7 Label A Internal View Label B Label B ...
Страница 36: ...1 22 This page is intentionally left blank ...
Страница 44: ...2 8 Front View inside Tower model Rack mount model ...
Страница 83: ...3 9 This page is intentionally left blank ...
Страница 84: ......
Страница 156: ...5 28 PCI Device Detailed information Allows the detailed information of a device on the PCI slot to be viewed ...
Страница 168: ...5 40 Sample screen of NEC ESMPRO Manager 2 Maintenance screen of CPU module CPU Module Maintenance ...
Страница 177: ...5 49 Not support ...
Страница 191: ...5 63 This page is intentionally left blank ...
Страница 192: ......
Страница 205: ...Chapter 7 Troubleshooting If the product does not work properly see this chapter before deciding that it is a breakdown ...
Страница 254: ...8 12 Check the disk status to confirm that the disk is added successfully ...
Страница 273: ...8 31 Chapter 7 Troubleshooting ...
Страница 283: ...8 41 18 Use cable ties to fasten the extra length of cables Cable ties included with cabinet ...
Страница 297: ...8 55 This page is intentionally left blank ...
Страница 298: ......
Страница 300: ...A 2 This page is intentionally left blank ...