5. RAID System Configuration
Express5800/R110i-1, T110i-S, T110i Maintenance Guide
127
Chapter 2 Useful Features
5.2
Menu Tree of the Legacy Mode
◇
: Selection/execution parameter
●
: Setting parameter.
・
: Information
◆
: Can be set (modified) after creation of Virtual Drive
Menu Description
◇
Configure
Setting of Configuration
◇
Easy Configuration
Setting of Configuration (fixed value used)
◇
New Configuration
Create new Configuration
◇
View/Add Configuration
Display or add Configuration
◇
Clear Configuration
Clear Configuration
◇
Select Boot Drive
Select bootable Virtual Drive
◇
Initialize
Initialize Virtual Drive
◇
Objects
Various settings
◇
Adapter
Configure RAID Controller
◇
Sel. Adapter
Select an adapter
●
Rebuild Rate
30 (Percentage of IO for Rebuild)
●
Chk Const Rate
30 (Percentage of IO for Check Consistency)
●
FGI Rate
30 (Percentage of IO for Foreground Initialize)
●
BGI Rate
30 (Percentage of IO for Background Initialize)
●
Disk WC
Off (Use or not use Write Cache of Adapter, unavailable on LSI Software
RAID.)
●
Read Ahead
On (On/Off Read Ahead)
●
Bios State
Enable (Enable or disable LSI Software RAID BIOS)
●
Continue on Error
Yes (If LSI Software RAID BIOS detects an error, specify whether the POST
halts or not.)
●
Fast Init
Enable (Enable or disable Fast Initialize)
●
Auto Rebuild
On (Enable or disable Auto Rebuild)
●
Auto Resume
Enable (If the system is restarted during Rebuild or Check Consistency,
specify whether the task is continued automatically or not.)
●
Disk Coercion
1GB (Forcibly pack HDDs of different size)
●
Factory Default
Restore the default value