1. System BIOS
Express5800/R110i-1, T110i-S, T110i Maintenance Guide
94
Chapter 2 Useful Features
(2/2)
Option Parameter
Description
Thermal Sensor
Disabled
[Enabled]
Enables or disables the thermal sensor
monitoring. If this option is set to
Enabled
and when abnormal temperature is detected,
the system stops at the end of POST.
Check previous System Config
[Disabled]
Enabled
If this option is set to
Enabled
and the
system configuration differs from the
previous boot, the system waits for user’s
intervention before booting.
BMC IRQ
[Disabled]
IRQ 11
Specifies whether to assign an interrupt line
to the BMC.
Post Error Pause
Disabled
[Enabled]
Specifies whether to stop the POST once at
the end of POST if an error occurs during the
POST.
Memory Error
Halt
[Boot]
Specifies whether to stop operation at the
end of POST processing if a memory
resource error occurred while executing
POST.
This option is enabled if
POST Error Pause
in the
Server
menu is enabled.
Even if this option is set to
Boot
, operation
stops at the end of POST if errors occurred
for all resources.
Power Switch Inhibit
[Disabled]
Enabled
Enables or disables the power switch inhibit
feature.
CLI SETUP
[Disabled]
Enabled
Specifies whether to use Command Line
Interface (CLI).
Enabled :
SETUP is run by CLI instead of
the menu operation. To switch back to the
menu operation, set this option to
Disabled
on CLI.