1. POST Error Message
Express5800/R110i-1, T110i-S, T110i Maintenance Guide
199
Chapter 3 Appendix
(2/4)
BMC Message on Lower LCD Line
Description
Action
DIMM Area Temperature Upper
Non-Critical
A temperature abnormality was
detected.
A cooling fan has a failure or is clogged
by dusts. Contact your sales
representative.
DIMM Area Temperature Lower
Critical
DIMM Area Temperature Upper
Critical
Processor Thermal Control
Upper Non-Critical
Processor Thermal Control
Upper Critical
DUMP Request !
The dump button was pressed.
Wait until collecting the memory dump
is complete.
OS shutdown Alm
An OS stop error occurred.
Write down the displayed message,
wait until collecting the memory dump
is complete, and then contact your
sales representative.
Power Supply1 Failure
detected
A power supply unit abnormality
occurred.
Make sure that the power cord is
plugged in.
Power Supply2 Failure
detected
Power Supply1 AC Lost
AC input of a power supply unit
was abnormality.
Power Supply2 AC Lost
Processor Missing
No CPU is installed.
Contact your sales representative.
Processor Thermal Trip
The power was forcibly turned off
due to a CPU temperature
abnormality.
DIMM1 Uncorrectable Error
An unrecoverable error occurred
for DIMM1.
DIMM2 Uncorrectable Error
An unrecoverable error occurred
for DIMM2.
DIMM3 Uncorrectable Error
An unrecoverable error occurred
for DIMM3.
DIMM4 Uncorrectable Error
An uncorrectable error occurred
for DIMM4.
Processor Internal Error
An internal CPU error (IERR)
occurred.
Sensor Failure Detected.
Abnormality in a sensor was
detected.
SMI timeout
A timeout occurred while
servicing system management
interrupts.
IPMI Watchdog timer timeout
(Power off)
A watchdog timer timeout
occurred.