7. Resetting and Clearing the Server
Express5800/R110i-1, T110i-S, T110i Maintenance Guide
45
Chapter 1 Maintenance
7.3
Forced Shutdown
Use this feature if an OS command does not shut down the server, POWER Switch does not turn off the
server, or software reset does not work.
Continue to hold POWER Switch of the server for at least four seconds. The power is forcibly turned off.
To turn on the power back again, wait at least 30 seconds after turning off the power.
Note
If the remote power-on feature is used, cycle the power once to load the OS after
the power has been forcibly turned off, and then turn off the power again by
shutting down the OS.
When the server is shut down forcibly, an event is logged 12 seconds after the
power switch is released. This event indicates that the system detected power
supply configuration had been non-redundant and the redundant configuration
was restored, and you can ignore this event.
If STATUS LED turns amber when the server is shut down forcibly, unplug the
power cord temporarily to turn off the STATUS LED.
T110i-S
R110i-1
2.5-inch Hard Disk Drive model
3.5-inch Hard Disk Drive model
POWER Switch
(Keep pressing for at least four seconds)
POWER Switch
(Keep pressing for at least four seconds)
POWER Switch
(Keep pressing for at least four seconds)